Trane / AIR-SOURCE HEAT PUMP

5TWR7024A1

17 Multi-Speed Heat Pump · source records, page 7

245 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.1–11BTU/Wh
Cooling capacity21,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 5TWR7024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 245 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1245 / 245
EER2 · BTU/Wh11.5–12.5245 / 245
HSPF2 · BTU/Wh8.1–11245 / 245
Cooling capacity · BTU/h21,000–24,000245 / 245
Heating capacity at 47°F / 8.3°C · BTU/h20,600–22,600245 / 245
Heating capacity at 17°F / −8.3°C · BTU/h14,800–15,800245 / 245
Heating capacity at 5°F / −15°C · BTU/h16,700–17,700245 / 245
COP at 5°F / −15°C1.8–2.1245 / 245
Equipment / loop typeHP - Split System245 / 245
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)245 / 245
Compressor stagingTwo-stage245 / 245
Connected capabilityNo245 / 245

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD04AS3+P0V0A000M30SDAHRI reference: 21676586817.108.10172001.84EPA 3983001
5PX*BD04AS3+ furnace: S9X1B060D3PSBAHRI reference: 21676587217.108.10172001.85EPA 3983002
5PX*BD04AS3+ furnace: S8V2B060M4PCBAHRI reference: 21676587417.108.10173001.84EPA 3983004
5PX*BD04AS3+ furnace: S8V2B080M4PCBAHRI reference: 21676587617.108.10171001.83EPA 3983006
5PX*BD04AS3+ furnace: S9V2B040D3VSBAHRI reference: 21676588417.108.10172001.84EPA 3983008
5PX*BD06AS3+ furnace: S9X1B060D3PSBCold climate designationAHRI reference: 21676589817.108.70174001.90EPA 3983011
5PX*BD06AS3+ furnace: S9V2B040D3VSBCold climate designationAHRI reference: 21676590217.108.70174001.90EPA 3983014
5PX*B004AS3+ furnace: S9X1B040U3PSBCold climate designationAHRI reference: 21676578617.108.70172002.00EPA 3983016
5PX*B004AS3+ furnace: S8V2B060M4PCBCold climate designationAHRI reference: 21676579017.108.70173002.00EPA 3983019
5PX*B004AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 21676579217.108.70172002.00EPA 3983020
5PX*B004AS3+P0V0B000M40SDCold climate designationAHRI reference: 21676579417.108.70170001.90EPA 3983023
5PX*B004AS3+ furnace: S8V2A040M3PCBCold climate designationAHRI reference: 21676579617.108.70173002.00EPA 3983025
5PX*B004AS3+P0V0A000M30SDCold climate designationAHRI reference: 21676579817.108.70173002.00EPA 3983026
5PX*B004AS3+ furnace: S9V2B060U4VSBCold climate designationAHRI reference: 21676582417.108.70172002.00EPA 3983036
5PX*BD06AS3+ furnace: S8V2B080M4PCBCold climate designationAHRI reference: 21676590417.108.70174001.90EPA 3983042
5PX*BD06AS3+ furnace: S8V2B060M4PCBCold climate designationAHRI reference: 21676590617.108.50173001.90EPA 3983044
5PX*BD06AS3+ furnace: S8V2A040M3PCBCold climate designationAHRI reference: 21676590817.108.70175001.90EPA 3983046
5PX*BD06AS3+P0V0B000M40SDAHRI reference: 21676591017.108.50171001.93EPA 3983048
5PX*BD06AS3+P0V0A000M30SDCold climate designationAHRI reference: 21676591217.108.70174001.90EPA 3983050
5PX*BD06AS3+ furnace: S9X1B040D3PSBCold climate designationAHRI reference: 21676591417.108.50173001.90EPA 3983052

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.