Trane / AIR-SOURCE HEAT PUMP

5TWR7024A1

17 Multi-Speed Heat Pump · source records, page 5

245 published source records · source checked Sep 21, 2026

SEER2 range15.2–17.1BTU/Wh
HSPF2 range8.1–11BTU/Wh
Cooling capacity21,000–24,000BTU/h

Each efficiency range summarizes published EPA records for 5TWR7024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 245 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17.1245 / 245
EER2 · BTU/Wh11.5–12.5245 / 245
HSPF2 · BTU/Wh8.1–11245 / 245
Cooling capacity · BTU/h21,000–24,000245 / 245
Heating capacity at 47°F / 8.3°C · BTU/h20,600–22,600245 / 245
Heating capacity at 17°F / −8.3°C · BTU/h14,800–15,800245 / 245
Heating capacity at 5°F / −15°C · BTU/h16,700–17,700245 / 245
COP at 5°F / −15°C1.8–2.1245 / 245
Equipment / loop typeHP - Split System245 / 245
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)245 / 245
Compressor stagingTwo-stage245 / 245
Connected capabilityNo245 / 245

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+ furnace: S9V2B060U3VSBCold climate designationAHRI reference: 21676354417.109.00174002.00EPA 3979928
5TXCB006AS3+ furnace: S9V2B060U4PSCCold climate designationAHRI reference: 21676354617.109.00174002.00EPA 3979930
5TXCB006AS3+ furnace: S9V2B080U4PSCCold climate designationAHRI reference: 21676354817.109.00174002.00EPA 3979931
5TXCB006AS3+ furnace: S9V2B080U4VSBCold climate designationAHRI reference: 21676355017.109.00174002.00EPA 3979934
5TXCB006AS3+ furnace: S9V2B080D4PSCCold climate designationAHRI reference: 21676355617.109.00171002.00EPA 3979935
5TXCB006AS3+ furnace: S9V2B060D3VSBCold climate designationAHRI reference: 21676355817.108.70168001.90EPA 3979936
5TXCB006AS3+ furnace: S9V2B080D4VSBCold climate designationAHRI reference: 21676355417.109.00171002.00EPA 3979937
5TXCB006AS3+ furnace: *DHMB060CCV3Cold climate designationAHRI reference: 21676355217.109.00169002.00EPA 3979940
5TXCB006AS3+ furnace: S9V2B060D3PSCCold climate designationAHRI reference: 21676356017.108.70168001.90EPA 3979943
5TXCB006AS3+ furnace: S9V2B040D3PSCCold climate designationAHRI reference: 21676356217.109.00171002.00EPA 3979948
5TXCC007AS3+ furnace: *DHMC100CCV4Cold climate designationAHRI reference: 21676356617.108.70168002.00EPA 3979949
5PX*B004AS3+ furnace: S8X2B060M4PTCCold climate designationAHRI reference: 21676454317.109.00171002.00EPA 3980693
5PX*B004AS3+ furnace: S8X2B080M4PSCCold climate designationAHRI reference: 21676453917.108.70170001.90EPA 3980694
5PX*B004AS3+ furnace: S8X2A040M3PTCCold climate designationAHRI reference: 21676454517.109.00172002.00EPA 3980696
5PX*B004AS3+ furnace: S8X2A040M3PSCCold climate designationAHRI reference: 21676454717.109.00172002.00EPA 3980700
5PX*B004AS3+ furnace: S8X2B080M4PTCCold climate designationAHRI reference: 21676454117.108.70170001.90EPA 3980701
5PX*B004AS3+ furnace: S8X2B060M4PSCCold climate designationAHRI reference: 21676455517.109.00171002.00EPA 3980702
5PX*B004AS3+ furnace: S8X1A040M3PTCCold climate designationAHRI reference: 21676455317.109.00172002.00EPA 3980703
5PX*B004AS3+ furnace: S8X1B060M4PTCCold climate designationAHRI reference: 21676454917.109.00171002.00EPA 3980704
5PX*B004AS3+ furnace: S8X1B040M2PTCCold climate designationAHRI reference: 21676455117.108.70171001.90EPA 3980709

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →