Trane / AIR-SOURCE HEAT PUMP

5TWR6036A1

16 Single-Stage Heat Pump · source records, page 8

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD09AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810778816.008.10172002.32EPA 4574958
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21810778616.008.10170002.33EPA 4574960
5PX*CD09AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810778416.008.10170002.38EPA 4574962
5PX*CD09AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21810778216.008.10173002.32EPA 4574964
5PX*CD09AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810778016.008.10172002.32EPA 4574966
5PX*CD09AS3+TSTAT+ furnace: S9V2C100D5VSBAHRI reference: 21810777816.008.10170002.33EPA 4574968
5PX*CD09AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810777616.008.10172002.32EPA 4574970
5PX*CD09AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810777416.008.10172002.32EPA 4574972
5PX*CD09AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810777216.008.10172002.32EPA 4574974
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810777016.008.10175002.31EPA 4574976
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810776616.008.10175002.31EPA 4574980
5PX*CD07AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810776216.008.10176002.31EPA 4574984
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21810776016.008.10176002.31EPA 4574986
5PX*CD07AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810775816.008.10176002.31EPA 4574988
5PX*CD07AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810775416.008.10173002.37EPA 4574992
5PX*CD07AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21810775216.008.10175002.31EPA 4574994
5PX*CD07AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21810775016.008.10176002.31EPA 4574996
5PX*CD07AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21810774816.008.10175002.31EPA 4574998
5PX*CD09AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21815920916.008.10171002.34EPA 4576635
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839557416.008.10173002.36EPA 4599449

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →