5TWR6036A1
16 Single-Stage Heat Pump · source records, page 6
371 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWR6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 371 / 371 |
| EER2 · BTU/Wh | 11.5–12 | 371 / 371 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 371 / 371 |
| Cooling capacity · BTU/h | 31,600–35,200 | 371 / 371 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 29,800–32,200 | 371 / 371 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 21,000–22,200 | 371 / 371 |
| Heating capacity at 5°F / −15°C · BTU/h | 16,900–17,600 | 371 / 371 |
| COP at 5°F / −15°C | 2.23–2.49 | 371 / 371 |
| Equipment / loop type | HP - Split System | 371 / 371 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 371 / 371 |
| Compressor staging | Single stage | 371 / 371 |
| Connected capability | No | 371 / 371 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5TEMCD05AV41+TDR+TSTATAHRI reference: 218107902 | 16.00 | 8.50 | 17000 | 2.46 | EPA 4574852 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 218107900 | 16.00 | 8.10 | 17000 | 2.46 | EPA 4574854 → |
5TEM6D07AV51+TDR+TSTATAHRI reference: 218107896 | 16.00 | 8.10 | 17100 | 2.48 | EPA 4574856 → |
5TEM6D06AV41+TDR+TSTATAHRI reference: 218107894 | 16.00 | 8.10 | 17100 | 2.48 | EPA 4574858 → |
5TEM6D05AV41+TDR+TSTATAHRI reference: 218107892 | 16.00 | 8.10 | 17300 | 2.43 | EPA 4574860 → |
5TEM6D04AV31+TDR+TSTATAHRI reference: 218107890 | 16.00 | 8.50 | 17500 | 2.38 | EPA 4574862 → |
5TAMXD07AV51+TSTATAHRI reference: 218107876 | 16.00 | 8.10 | 16900 | 2.35 | EPA 4574872 → |
5TAMXD06AV41+TSTATAHRI reference: 218107874 | 16.00 | 8.10 | 17100 | 2.38 | EPA 4574874 → |
5TAMXD05AV41+TSTATAHRI reference: 218107872 | 16.00 | 8.10 | 17100 | 2.38 | EPA 4574876 → |
5TAM5D06AC41+TSTATAHRI reference: 218107866 | 16.00 | 8.10 | 17100 | 2.36 | EPA 4574882 → |
5TAM5D05AC31+TSTATAHRI reference: 218107864 | 16.00 | 8.10 | 17200 | 2.34 | EPA 4574884 → |
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 218107858 | 16.00 | 8.10 | 17100 | 2.37 | EPA 4574888 → |
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 218107852 | 16.00 | 8.10 | 17300 | 2.35 | EPA 4574894 → |
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 218107850 | 16.00 | 8.10 | 17300 | 2.35 | EPA 4574896 → |
5PX*DD10AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 218107848 | 16.00 | 8.10 | 17300 | 2.35 | EPA 4574898 → |
5PX*DD10AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 218107846 | 16.00 | 8.10 | 17300 | 2.35 | EPA 4574900 → |
5PX*DD10AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 218107844 | 16.00 | 8.10 | 17100 | 2.37 | EPA 4574902 → |
5PX*D010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 218107842 | 16.00 | 8.10 | 17300 | 2.39 | EPA 4574904 → |
5PX*D010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 218107840 | 16.00 | 8.10 | 17300 | 2.39 | EPA 4574906 → |
5PX*D010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 218107838 | 16.00 | 8.10 | 17200 | 2.39 | EPA 4574908 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →