Trane / AIR-SOURCE HEAT PUMP

5TWR6036A1

16 Single-Stage Heat Pump · source records, page 3

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*BD06AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21810757616.008.00173002.35EPA 4573555
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21810757416.008.10172002.35EPA 4573557
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21810757216.008.00176002.32EPA 4573559
5PX*BD06AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21810757016.008.00173002.35EPA 4573561
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21810756816.008.10172002.35EPA 4573563
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21810756616.008.00176002.32EPA 4573565
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810755816.008.10171002.40EPA 4573573
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810754616.008.10172002.35EPA 4573585
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21810754416.008.00176002.32EPA 4573587
5PX*BD06AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810754216.008.00173002.35EPA 4573589
5PX*BD06AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21810754016.008.10172002.35EPA 4573591
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21810753816.008.00176002.32EPA 4573593
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21810745616.008.10171002.41EPA 4573621
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21810820616.008.10171002.42EPA 4574594
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21810820016.008.10173002.39EPA 4574600
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21810819816.008.10173002.39EPA 4574602
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21810819616.008.10173002.39EPA 4574604
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21810819416.008.10173002.39EPA 4574606
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21810819216.008.10171002.42EPA 4574608
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810819016.008.10170002.41EPA 4574610

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →