Trane / AIR-SOURCE HEAT PUMP

5TWR6036A1

16 Single-Stage Heat Pump · source records, page 10

371 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,600–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 371 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5371 / 371
EER2 · BTU/Wh11.5–12371 / 371
HSPF2 · BTU/Wh7.8–8.5371 / 371
Cooling capacity · BTU/h31,600–35,200371 / 371
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,200371 / 371
Heating capacity at 17°F / −8.3°C · BTU/h21,000–22,200371 / 371
Heating capacity at 5°F / −15°C · BTU/h16,900–17,600371 / 371
COP at 5°F / −15°C2.23–2.49371 / 371
Equipment / loop typeHP - Split System371 / 371
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)371 / 371
Compressor stagingSingle stage371 / 371
Connected capabilityNo371 / 371

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21810761415.208.10170002.35EPA 4573521
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21810761215.208.10171002.34EPA 4573523
5PX*C005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21810761015.208.10170002.32EPA 4573525
5PX*C005AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21810760815.208.10174002.31EPA 4573527
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21810760615.208.10174002.32EPA 4573529
5PX*C005AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21810760415.208.10174002.31EPA 4573531
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21810760215.208.10174002.32EPA 4573533
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810760015.208.10172002.32EPA 4573535
5PX*C005AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21810759815.208.10172002.32EPA 4573537
5PX*C005AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810759215.208.10171002.33EPA 4573539
5PX*C005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810759015.208.10170002.33EPA 4573541
5PX*BD06AS3+TSTAT+P0V0A000M30SDAHRI reference: 21810758815.207.80172002.34EPA 4573543
5PX*BD06AS3+TSTAT+ furnace: S9X2B060D3PSBAHRI reference: 21810758415.208.10173002.35EPA 4573547
5PX*BD06AS3+TSTAT+ furnace: S9X1B080D4PSBAHRI reference: 21810758215.208.10173002.33EPA 4573549
5PX*BD06AS3+TSTAT+ furnace: S9X1B040D3PSBAHRI reference: 21810758015.208.10175002.32EPA 4573551
5PX*BD06AS3+TSTAT+ furnace: S9V2B060D3VSBAHRI reference: 21810757815.208.10171002.33EPA 4573553
5PX*BD06AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810756415.208.10172002.37EPA 4573567
5PX*BD06AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21810756215.208.10172002.36EPA 4573569
5PX*BD06AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810756015.208.00172002.35EPA 4573571
5PX*BD06AS3+TSTAT+ furnace: *DHMB060CCV3AHRI reference: 21810755615.208.10171002.32EPA 4573575