Trane / AIR-SOURCE HEAT PUMP

5TWR6030A1

16 Single-Stage Heat Pump · source records, page 2

143 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity27,000–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR6030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 143 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16143 / 143
EER2 · BTU/Wh11.7–12143 / 143
HSPF2 · BTU/Wh7.8–8.1143 / 143
Cooling capacity · BTU/h27,000–29,200143 / 143
Heating capacity at 47°F / 8.3°C · BTU/h24,800–26,800143 / 143
Heating capacity at 17°F / −8.3°C · BTU/h16,800–17,700143 / 143
Heating capacity at 5°F / −15°C · BTU/h13,100–13,800143 / 143
COP at 5°F / −15°C2.12–2.28143 / 143
Equipment / loop typeHP - Split System143 / 143
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)143 / 143
Compressor stagingSingle stage143 / 143
Connected capabilityNo143 / 143

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811189716.008.00132002.19EPA 4575617
5TXCC009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811189316.008.00132002.19EPA 4575621
5TXCC009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811188916.008.10134002.20EPA 4575625
5TEMCD07AV51+TDR+TSTATAHRI reference: 21811182716.008.10131002.28EPA 4575641
5TEMCD06AV41+TDR+TSTATAHRI reference: 21811182516.008.10131002.28EPA 4575643
5PX*C009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21811177316.008.00132002.19EPA 4575661
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21811177116.008.10132002.20EPA 4575663
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21811176916.008.10132002.20EPA 4575665
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21811176716.008.10134002.20EPA 4575667
5PX*C009AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21811176316.008.00132002.19EPA 4575671
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21839540016.008.10135002.18EPA 4599509
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21839522616.008.00131002.19EPA 4599567
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21839522416.008.10138002.12EPA 4599569
5PX*B006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21839522216.008.10138002.12EPA 4599571
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21810735015.207.80131002.23EPA 4573683
5TXCC007AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21810734015.207.80134002.19EPA 4573687
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21810733615.208.10134002.19EPA 4573691
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21810733415.208.10134002.19EPA 4573693
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21810733215.207.80133002.18EPA 4573695
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PCBAHRI reference: 21810733015.207.80135002.17EPA 4573697