Trane / AIR-SOURCE HEAT PUMP

5TWR6024A1

16 Single-Stage Heat Pump · source records, page 5

126 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWR6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17126 / 126
EER2 · BTU/Wh11.7–12126 / 126
HSPF2 · BTU/Wh7.8–8.1126 / 126
Cooling capacity · BTU/h23,200–24,800126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,200126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,000126 / 126
Heating capacity at 5°F / −15°C · BTU/h11,000–11,500126 / 126
COP at 5°F / −15°C2.12–2.28126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingSingle stage126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21810626016.007.80114002.14EPA 4573987
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21810625816.008.10111002.20EPA 4573989
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 21810625616.008.00112002.19EPA 4573991
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21810625416.008.00115002.16EPA 4573993
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810625216.008.00115002.16EPA 4573995
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21810625016.008.00113002.17EPA 4573997
5PX*B006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810624816.008.00113002.18EPA 4573999
5PX*B006AS3+TSTAT+ furnace: S9V2B060U3VSBAHRI reference: 21810624616.008.00113002.16EPA 4574001
5PX*B006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21810624416.008.10113002.17EPA 4574003
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21811164316.008.10113002.16EPA 4575695
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21811164116.008.10113002.16EPA 4575697
5TXCB006AS3+TSTAT+ furnace: S8X1B040M2PSCAHRI reference: 21811163916.008.10113002.17EPA 4575699
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21811163716.008.10113002.16EPA 4575701
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21811163516.008.10113002.16EPA 4575703
5TXCB006AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 21811163316.008.10113002.17EPA 4575705
5TXCB006AS3+TSTAT+ furnace: S9X1B040U3PSBAHRI reference: 21811162716.008.10112002.18EPA 4575711
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21811162516.008.10113002.18EPA 4575713
5TXCB006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21811162316.008.10112002.18EPA 4575715
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21811162116.008.10113002.18EPA 4575717
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21811153116.008.10112002.18EPA 4575735

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →