Trane / AIR-SOURCE HEAT PUMP

5TWR6024A1

16 Single-Stage Heat Pump

126 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity23,200–24,800BTU/h

Each efficiency range summarizes published EPA records for 5TWR6024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 126 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17126 / 126
EER2 · BTU/Wh11.7–12126 / 126
HSPF2 · BTU/Wh7.8–8.1126 / 126
Cooling capacity · BTU/h23,200–24,800126 / 126
Heating capacity at 47°F / 8.3°C · BTU/h21,000–23,200126 / 126
Heating capacity at 17°F / −8.3°C · BTU/h14,300–15,000126 / 126
Heating capacity at 5°F / −15°C · BTU/h11,000–11,500126 / 126
COP at 5°F / −15°C2.12–2.28126 / 126
Equipment / loop typeHP - Split System126 / 126
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)126 / 126
Compressor stagingSingle stage126 / 126
Connected capabilityNo126 / 126

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TEMCD07AV51+TDR+TSTATAHRI reference: 21810651017.007.80110002.28EPA 4573873
5TEMCD06AV41+TDR+TSTATAHRI reference: 21810650817.007.80110002.26EPA 4573875
5TXCC009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810673216.508.00112002.21EPA 4573815
5PX*C009AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810646416.508.00112002.21EPA 4573905
5PX*BD06AS3+TSTAT+ furnace: S9V2B060D3VSBAHRI reference: 21810644816.508.10112002.15EPA 4573915
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21811159716.508.10113002.15EPA 4575723
5PX*BD06AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21811159516.508.10113002.15EPA 4575725
5PX*BD06AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 21811159316.508.10112002.14EPA 4575727
5PX*BD06AS3+TSTAT+ furnace: S8X1B040M2PSCAHRI reference: 21811159116.508.10112002.14EPA 4575729
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21811158916.508.10113002.15EPA 4575731
5PX*BD06AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21811158716.508.10113002.15EPA 4575733
5TXCC007AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21810673016.008.10113002.20EPA 4573817
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21810672616.007.80113002.17EPA 4573819
5TXCB006AS3+TSTAT+ furnace: S8V2A040M3PDBAHRI reference: 21810672216.007.80113002.17EPA 4573823
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21810672016.008.10113002.17EPA 4573825
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21810671816.008.10113002.18EPA 4573827
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21810671616.008.10113002.17EPA 4573829
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21810671416.007.80114002.16EPA 4573831
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21810671216.007.80114002.18EPA 4573833
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21810671016.007.80114002.16EPA 4573835

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →