Trane / AIR-SOURCE HEAT PUMP

5TWR5042A1

15 Single-Stage Heat Pump · Silver 15 · source records, page 4

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C007AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556890616.008.10196002.10EPA 3650187
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556890816.008.10197002.10EPA 3650189
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556891016.008.10192002.10EPA 3650192
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556891216.008.10192002.10EPA 3650195
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556891416.008.10194002.10EPA 3650200
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556891616.008.10194002.10EPA 3650201
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556891816.008.10194002.10EPA 3650229
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556892016.008.10193002.10EPA 3650231
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556892216.008.10193002.10EPA 3650233
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21556892416.008.10194002.10EPA 3650236
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21556892616.008.10194002.10EPA 3650237
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556892816.008.10193002.10EPA 3650239
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556893216.008.10194002.10EPA 3650244
5PX*C007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556893416.008.10194002.10EPA 3650246
5PX*C007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556893616.008.10193002.10EPA 3650247
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556893816.008.10197002.10EPA 3650249
5PX*C009AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21556894216.008.10195002.10EPA 3650253
5PX*C009AS3+TSTAT+ furnace: S9X2C100U5PSBAHRI reference: 21556894416.008.10195002.10EPA 3650255
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556894616.008.10192002.20EPA 3650257
5PX*C009AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556894816.008.10192002.20EPA 3650259

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →