Trane / AIR-SOURCE HEAT PUMP

5TWR5042A1

15 Single-Stage Heat Pump · Silver 15 · source records, page 2

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21407897516.008.10191002.20EPA 3423538 →
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21407889116.008.10193002.10EPA 3424018 →
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21407889316.008.10194002.10EPA 3424019 →
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21407887516.008.10194002.10EPA 3424190 →
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21407887916.008.10194002.10EPA 3424194 →
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21407888116.008.10193002.10EPA 3424196 →
5TXCC007AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21407888316.008.10193002.10EPA 3424198 →
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21407888516.008.10194002.10EPA 3424199 →
5TXCC007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21407888716.008.10194002.10EPA 3424202 →
5TXCC007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21407888916.008.10193002.10EPA 3424204 →
5TEM6D04AV31+TDR+TSTATAHRI reference: 21407880716.008.50191002.20EPA 3424504 →
5TEM6D06AV41+TDR+TSTATAHRI reference: 21407880916.008.50194002.20EPA 3424506 →
5TEM6D07AV51+TDR+TSTATAHRI reference: 21407881116.008.50194002.20EPA 3424508 →
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21407896716.008.10190002.20EPA 3424665 →
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21407896916.008.10190002.20EPA 3424667 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDAAHRI reference: 21407897116.008.10191002.20EPA 3424669 →
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCAAHRI reference: 21407897316.008.10191002.20EPA 3424670 →
5TXCC007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21407889516.008.10194002.10EPA 3424843 →
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21407889916.008.10193002.10EPA 3424847 →
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21407890116.008.10193002.10EPA 3424849 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →