Trane / AIR-SOURCE HEAT PUMP

5TWR5042A1

15 Single-Stage Heat Pump · Silver 15 · source records, page 13

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*B006AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21556878415.208.10194002.10EPA 3650082
5PX*B006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21556878015.208.00192002.10EPA 3650083
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21556878615.208.00192002.10EPA 3650085
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21556879015.208.00193002.10EPA 3650088
5PX*B006AS3+TSTAT+ furnace: S8V2B080M4PCBAHRI reference: 21556879215.208.00193002.10EPA 3650090
5PX*B006AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21556878815.208.00192002.10EPA 3650091
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PDBAHRI reference: 21556879415.208.00193002.10EPA 3650093
5PX*B006AS3+TSTAT+ furnace: S8V2B060M4PCBAHRI reference: 21556879615.208.00193002.10EPA 3650096
5PX*B006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21556879815.208.10193002.10EPA 3650098
5PX*C005AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556884415.208.00194002.10EPA 3650165
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556884615.208.00194002.10EPA 3650167
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PCBAHRI reference: 21556886815.208.00195002.10EPA 3650168
5PX*C005AS3+TSTAT+ furnace: S8V2C100M5PDBAHRI reference: 21556887015.208.00195002.10EPA 3650170
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21556887215.208.00194002.10EPA 3650173
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PTCAHRI reference: 21556887415.208.00194002.10EPA 3650175
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556888015.208.00194002.10EPA 3650177
5PX*C005AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556888215.208.00194002.10EPA 3650179
5PX*C005AS3+TSTAT+ furnace: *UHMC100CCV4AHRI reference: 21556885615.208.00193002.10EPA 3650191
5PX*C005AS3+TSTAT+ furnace: L8V1C100U5VSBAHRI reference: 21556885815.208.00194002.10EPA 3650197
5PX*C005AS3+TSTAT+P0V0C000M50SDAHRI reference: 21556886215.208.10195002.10EPA 3650202

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →