Trane / AIR-SOURCE HEAT PUMP

5TWR5042A1

15 Single-Stage Heat Pump · Silver 15 · source records, page 11

293 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity37,400–41,500BTU/h

Each efficiency range summarizes published EPA records for 5TWR5042A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 293 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17293 / 293
EER2 · BTU/Wh11.7–12293 / 293
HSPF2 · BTU/Wh7.8–8.5293 / 293
Cooling capacity · BTU/h37,400–41,500293 / 293
Heating capacity at 47°F / 8.3°C · BTU/h37,400–40,500293 / 293
Heating capacity at 17°F / −8.3°C · BTU/h24,600–26,400293 / 293
Heating capacity at 5°F / −15°C · BTU/h18,700–20,000293 / 293
COP at 5°F / −15°C2–2.3293 / 293
Equipment / loop typeHP - Split System293 / 293
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)293 / 293
Compressor stagingSingle stage293 / 293
Connected capabilityNo293 / 293

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21407884715.207.80192002.10EPA 3424162
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21407884915.207.80192002.10EPA 3424163
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 21407885115.208.10193002.10EPA 3424166
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21407885315.208.10193002.10EPA 3424168
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSBAHRI reference: 21407885515.208.10193002.10EPA 3424170
5TXCB006AS3+TSTAT+ furnace: S9V2B060U4PSCAHRI reference: 21407885715.208.10193002.10EPA 3424172
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSBAHRI reference: 21407885915.208.10193002.10EPA 3424174
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4PSCAHRI reference: 21407886115.208.10195002.10EPA 3424175
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 21407886315.208.10196002.10EPA 3424178
5TXCB006AS3+TSTAT+ furnace: S9V2B080U4VSBAHRI reference: 21407886515.208.10196002.10EPA 3424180
5TXCB006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 21407886715.208.10192002.10EPA 3424181
5TXCB006AS3+TSTAT+ furnace: S9X1B080U4PSBAHRI reference: 21407886915.208.10192002.10EPA 3424185
5TXCC007AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21407887115.208.10194002.10EPA 3424186
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PCAAHRI reference: 21407887315.208.10193002.10EPA 3424188
5TXCC007AS3+TSTAT+ furnace: S8V2C100M5PDAAHRI reference: 21407887715.208.10193002.10EPA 3424192
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21407881315.208.10192002.10EPA 3424510
5TXCC007AS3+TSTAT+ furnace: S9V2C080U5PSBAHRI reference: 21407889715.208.10192002.10EPA 3424845
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407890515.208.10192002.10EPA 3424853
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21407890915.208.10192002.10EPA 3424857
5TXCC007AS3+TSTAT+ furnace: S9X1C100U5PSBAHRI reference: 21407891115.208.10193002.10EPA 3424859

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →