Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 8

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*C009AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556853016.008.10171002.30EPA 3650935
5PX*C009AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556853216.008.10171002.30EPA 3650937
5PX*C009AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556853416.008.10171002.30EPA 3650939
5PX*C009AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556853616.008.10172002.30EPA 3650941
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PSCAHRI reference: 21556846416.008.10174002.30EPA 3650942
5PX*C007AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21556846616.008.10174002.30EPA 3650944
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556846816.008.10175002.30EPA 3650946
5PX*C007AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556847016.008.10175002.30EPA 3650948
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556847216.008.10174002.30EPA 3650950
5PX*C007AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556847416.008.10174002.30EPA 3650952
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556847616.008.10178002.30EPA 3650954
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556847816.008.50176002.30EPA 3650956
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556848016.008.50177002.30EPA 3650958
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556848216.008.10174002.30EPA 3650960
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556848616.008.10174002.30EPA 3650965
5PX*C009AS3+TSTAT+ furnace: S8X2C100M5PSCAHRI reference: 21556849016.008.10173002.30EPA 3650967
5PX*C009AS3+TSTAT+ furnace: S8X2C100M5PTCAHRI reference: 21556849216.008.10173002.30EPA 3650970
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PTCAHRI reference: 21556849416.008.10174002.30EPA 3650972
5PX*C009AS3+TSTAT+ furnace: S8X2C080M5PSCAHRI reference: 21556849616.008.10174002.30EPA 3650974
5PX*C009AS3+TSTAT+ furnace: S8X1C100M5PTCAHRI reference: 21556849816.008.10173002.30EPA 3650976

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →