Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 24

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5PX*CD07AS3+TSTAT+ furnace: *DHMC100CCV4AHRI reference: 21556857815.208.10175002.20EPA 3651069 →
5TEM4D07AC51+TDR+TSTATAHRI reference: 21561094115.208.10173002.40EPA 3651437 →
5TEM4D04AC31+TDR+TSTATAHRI reference: 21561093515.208.10171002.30EPA 3651477 →
5TEM4D05AC41+TDR+TSTATAHRI reference: 21561093715.208.10173002.30EPA 3651479 →
5TEM4D06AC41+TDR+TSTATAHRI reference: 21561093915.208.10172002.40EPA 3651481 →
5TEMCB03AV31+TDR+TSTATAHRI reference: 21586393215.208.10174002.30EPA 3737604 →
5PX*B004AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21583145215.208.10173002.20EPA 3737657 →
5PX*BD06AS3+TSTAT+ furnace: S9V2B040D3VSBAHRI reference: 21583145815.208.10175002.20EPA 3737661 →
5PX*C005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583146015.208.10174002.20EPA 3737663 →
5PX*C005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583146215.208.10175002.20EPA 3737665 →
5TXCB004AS3+TSTAT+ furnace: S9V2B060U4VSBAHRI reference: 21583148015.208.10173002.20EPA 3737679 →
5TXCC005AS3+TSTAT+ furnace: S9V2C100U5VSBAHRI reference: 21583148415.208.10172002.30EPA 3737683 →
5TXCC005AS3+TSTAT+ furnace: S9V2C080U5VSBAHRI reference: 21583148615.208.10174002.20EPA 3737685 →
5TAM5C04AC31+TSTATAHRI reference: 21602194915.208.10172002.30EPA 3845925 →
5TAMXC03AV31+TSTATAHRI reference: 21605696815.208.10175002.20EPA 3845947 →
5TAMXD04AV31+TSTATAHRI reference: 21605697015.208.10172002.30EPA 3845949 →
5TEM4B04AC31+TDR+TSTATAHRI reference: 21815461515.208.10174002.20EPA 4575868 →
5PX*CD07AS3+TSTAT+ furnace: S9X2C100D5PSBAHRI reference: 21836373815.208.10175002.20EPA 4591072 →
5PX*C005AS3+TSTAT+ furnace: S8X1C080M5PSCAHRI reference: 21836373615.208.10175002.20EPA 4591074 →
5PX*BD06AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21836373415.208.10175002.20EPA 4591076 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →