Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 2

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21407876916.008.10176002.30EPA 3424464
5TXCC007AS3+TSTAT+ furnace: S9V2C100U4VSAAHRI reference: 21407876716.008.10171002.30EPA 3424466
5TXCC007AS3+TSTAT+ furnace: S9V2C100U5PSBAHRI reference: 21407877116.008.10171002.30EPA 3424468
5TXCC007AS3+TSTAT+ furnace: S8V2C080M5PDBAHRI reference: 21407877316.008.10172002.30EPA 3424469
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSBAHRI reference: 21407877716.008.10169002.40EPA 3424473
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5VSAAHRI reference: 21407877916.008.10173002.30EPA 3424476
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSCAHRI reference: 21407878116.008.10169002.40EPA 3424478
5TXCD010AS3+TSTAT+ furnace: S9V2D120U5PSBAHRI reference: 21407878316.008.10169002.40EPA 3424480
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PTCAHRI reference: 21407878516.008.10172002.30EPA 3424482
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDAAHRI reference: 21407878716.008.10169002.30EPA 3424484
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCBAHRI reference: 21407878916.008.10169002.30EPA 3424486
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PCAAHRI reference: 21407879116.008.10169002.30EPA 3424488
5TXCD010AS3+TSTAT+ furnace: *UHMD120CCV5AHRI reference: 21407879316.008.10170002.30EPA 3424490
5TXCD010AS3+TSTAT+ furnace: *UHMD120ACV5AHRI reference: 21407879516.008.10170002.30EPA 3424492
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PTCAHRI reference: 21407879716.008.10172002.30EPA 3424494
5TXCD010AS3+TSTAT+ furnace: S8X1D120M5PSCAHRI reference: 21407879916.008.10172002.30EPA 3424495
5TXCD010AS3+TSTAT+ furnace: S8X2D120M5PSCAHRI reference: 21407880316.008.10172002.30EPA 3424500
5TXCD010AS3+TSTAT+ furnace: S8V2D120M5PDBAHRI reference: 21407880516.008.10169002.30EPA 3424502
5TXCC007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21407873516.008.10171002.30EPA 3424915
5TXCC007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21407873716.008.10171002.30EPA 3424917

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →