Trane / AIR-SOURCE HEAT PUMP

5TWR5036A1

15 Single-Stage Heat Pump · source records, page 14

481 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity31,800–35,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5036A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 481 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.5481 / 481
EER2 · BTU/Wh11.7–12481 / 481
HSPF2 · BTU/Wh7.8–8.5481 / 481
Cooling capacity · BTU/h31,800–35,200481 / 481
Heating capacity at 47°F / 8.3°C · BTU/h29,800–32,800481 / 481
Heating capacity at 17°F / −8.3°C · BTU/h20,800–22,400481 / 481
Heating capacity at 5°F / −15°C · BTU/h16,600–17,800481 / 481
COP at 5°F / −15°C2.1–2.4481 / 481
Equipment / loop typeHP - Split System481 / 481
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)481 / 481
Compressor stagingSingle stage481 / 481
Connected capabilityNo481 / 481

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 21407863115.208.10172002.30EPA 3424266
5TXCB006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407863315.208.10173002.30EPA 3424268
5TXCB006AS3+TSTAT+ furnace: L8V1A040U3VSBAHRI reference: 21407863515.207.80167002.20EPA 3424270
5TXCB006AS3+TSTAT+ furnace: L8V1A060U3VSBAHRI reference: 21407863715.208.10168002.20EPA 3424272
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSBAHRI reference: 21407863915.208.10171002.30EPA 3424275
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3PSCAHRI reference: 21407864115.208.10173002.30EPA 3424276
5TXCB006AS3+TSTAT+ furnace: L8V1B080U4VSBAHRI reference: 21407864315.208.10173002.30EPA 3424278
5TXCB006AS3+TSTAT+ furnace: L9X1B070U4VSAAHRI reference: 21407864515.207.80177002.20EPA 3424280
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSAAHRI reference: 21407864715.208.10171002.30EPA 3424282
5TXCB006AS3+TSTAT+ furnace: S9V2B040U3VSBAHRI reference: 21407864915.208.10171002.30EPA 3424284
5TXCB006AS3+TSTAT+P0V0A000M30SDAHRI reference: 21407865115.208.10168002.20EPA 3424286
5TXCB004AS3+TSTAT+ furnace: S8V2B080M4PDBAHRI reference: 21407852715.208.10174002.20EPA 3424440
5TXCB004AS3+TSTAT+ furnace: S8X1B060M4PSCAHRI reference: 21407852915.208.10175002.20EPA 3424442
5TXCB004AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 21407853115.208.10175002.20EPA 3424444
5TXCB004AS3+TSTAT+ furnace: S8X1B080M4PSCAHRI reference: 21407853315.207.80173002.20EPA 3424446
5TXCB004AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 21407853515.207.80173002.20EPA 3424449
5TXCB004AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 21407853715.207.80174002.20EPA 3424450
5TXCB004AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21407853915.207.80174002.20EPA 3424452
5TXCB004AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 21407854115.208.10175002.20EPA 3424454
5TXCB004AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 21407854315.208.10175002.20EPA 3424456

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.