Trane / AIR-SOURCE HEAT PUMP

5TWR5030A1

15 Single-Stage Heat Pump

140 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity26,400–29,200BTU/h

Each efficiency range summarizes published EPA records for 5TWR5030A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 140 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16140 / 140
EER2 · BTU/Wh11.7–12140 / 140
HSPF2 · BTU/Wh7.8–8.1140 / 140
Cooling capacity · BTU/h26,400–29,200140 / 140
Heating capacity at 47°F / 8.3°C · BTU/h24,200–26,400140 / 140
Heating capacity at 17°F / −8.3°C · BTU/h16,300–17,700140 / 140
Heating capacity at 5°F / −15°C · BTU/h12,700–13,800140 / 140
COP at 5°F / −15°C2–2.2140 / 140
Equipment / loop typeHP - Split System140 / 140
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)140 / 140
Compressor stagingSingle stage140 / 140
Connected capabilityNo140 / 140

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21407839116.008.10129002.00EPA 3423791
5TXCB006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21407839316.008.10129002.00EPA 3423796
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21407840316.008.10129002.00EPA 3423803
5TXCB006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21407840516.008.10129002.00EPA 3423809
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PSCAHRI reference: 21556776016.008.10127002.00EPA 3649919
5PX*B006AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 21556771816.008.10138002.10EPA 3649922
5PX*B006AS3+TSTAT+ furnace: S9X2B080U4PSBAHRI reference: 21556772216.008.00137002.10EPA 3649924
5PX*B006AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556773416.008.10135002.10EPA 3649926
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PSCAHRI reference: 21556774816.008.10127002.00EPA 3649928
5PX*B006AS3+TSTAT+ furnace: S8X1A040M3PTCAHRI reference: 21556775016.008.10127002.00EPA 3649930
5PX*B006AS3+TSTAT+ furnace: S8X2A040M3PTCAHRI reference: 21556776216.008.10127002.00EPA 3649932
5PX*B006AS3+TSTAT+ furnace: *UHMB080CCV3AHRI reference: 21556778016.008.00134002.10EPA 3650016
5PX*BD06AS3+TSTAT+P0V0B000M40SDAHRI reference: 21556786816.008.10137002.10EPA 3650019
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D5PSCAHRI reference: 21556800816.008.10136002.10EPA 3650121
5PX*CD07AS3+TSTAT+ furnace: S9V2C100D4VSBAHRI reference: 21556801016.008.10136002.10EPA 3650123
5PX*C007AS3+TSTAT+ furnace: S9X2C080U5PSBAHRI reference: 21556794616.008.00133002.10EPA 3650137
5PX*C007AS3+TSTAT+ furnace: S9X1C080U5PSBAHRI reference: 21556794816.008.00133002.10EPA 3650139
5PX*C007AS3+TSTAT+ furnace: S9V2C100U5PSCAHRI reference: 21556795016.008.10135002.10EPA 3650141
5PX*C007AS3+TSTAT+ furnace: S9V2C100U4VSBAHRI reference: 21556795216.008.10135002.10EPA 3650143
5PX*C007AS3+TSTAT+ furnace: S9V2C080U5PSCAHRI reference: 21556795416.008.10136002.10EPA 3650144

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →