5TWR5024A1
15 Single-Stage Heat Pump
30 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 5TWR5024A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 30 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16.5 | 30 / 30 |
| EER2 · BTU/Wh | 12 | 30 / 30 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 30 / 30 |
| Cooling capacity · BTU/h | 22,800–25,000 | 30 / 30 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 21,000–22,800 | 30 / 30 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,000–14,900 | 30 / 30 |
| Heating capacity at 5°F / −15°C · BTU/h | 10,900–11,400 | 30 / 30 |
| COP at 5°F / −15°C | 2–2.2 | 30 / 30 |
| Equipment / loop type | HP - Split System | 30 / 30 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 30 / 30 |
| Compressor staging | Single stage | 30 / 30 |
| Connected capability | No | 30 / 30 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
5PX*B006AS3+TSTAT+ furnace: *UHMB060CCV3AHRI reference: 215567326 | 16.50 | 8.00 | 11300 | 2.10 | EPA 3650115 → |
5TEMCD06AV41+TDR+TSTATAHRI reference: 215863920 | 16.50 | 7.80 | 11000 | 2.20 | EPA 3737592 → |
5TEMCD07AV51+TDR+TSTATAHRI reference: 215863922 | 16.50 | 7.80 | 11000 | 2.20 | EPA 3737594 → |
5TXCB006AS3+TSTAT+ furnace: S8V2B080M4PDAAHRI reference: 214078335 | 16.00 | 7.80 | 11100 | 2.10 | EPA 3423673 → |
5TXCB006AS3+TSTAT+ furnace: S8X1B060M4PTCAHRI reference: 214078337 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423675 → |
5TXCB006AS3+TSTAT+ furnace: S8X1B080M4PTCAHRI reference: 214078339 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423677 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PSCAHRI reference: 214078341 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423679 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B060M4PTCAHRI reference: 214078343 | 16.00 | 7.80 | 11300 | 2.10 | EPA 3423681 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PSCAHRI reference: 214078345 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423683 → |
5TXCB006AS3+TSTAT+ furnace: S8X2B080M4PTCAHRI reference: 214078347 | 16.00 | 7.80 | 11400 | 2.10 | EPA 3423685 → |
5TXCB006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 214078327 | 16.00 | 8.10 | 11400 | 2.10 | EPA 3424728 → |
5PX*B006AS3+TSTAT+ furnace: S9X1B060U4PSBAHRI reference: 215567322 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3650111 → |
5PX*B006AS3+TSTAT+ furnace: S9X2B060U4PSBAHRI reference: 215567324 | 16.00 | 8.00 | 11400 | 2.10 | EPA 3650113 → |
5TEMCD04AV31+TDR+TSTATAHRI reference: 215863916 | 16.00 | 8.10 | 11100 | 2.20 | EPA 3737588 → |
5TEMCD05AV41+TDR+TSTATAHRI reference: 215863918 | 16.00 | 8.10 | 11100 | 2.20 | EPA 3737590 → |
5TAMXD05AV41+TSTATAHRI reference: 216056954 | 16.00 | 8.10 | 11100 | 2.10 | EPA 3845941 → |
5TEM4B04AC31+TDR+TSTATAHRI reference: 218154611 | 16.00 | 8.00 | 11300 | 2.10 | EPA 4575872 → |
5TXCB004AS3+TSTAT+ furnace: S8X1B040M2PTCAHRI reference: 214078317 | 15.20 | 7.80 | 11000 | 2.00 | EPA 3424717 → |
5TXCB004AS3+TSTAT+ furnace: S9V2B080U4VSAAHRI reference: 214078319 | 15.20 | 7.80 | 11300 | 2.10 | EPA 3424719 → |
5TXCB004AS3+TSTAT+ furnace: S9X2B040U3PSBAHRI reference: 214078321 | 15.20 | 7.80 | 11100 | 2.10 | EPA 3424721 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →