4TWV8X60A1
XV18 · XV18I
85 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4TWV8X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 85 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 18 | 85 / 85 |
| EER2 · BTU/Wh | 11.7–12 | 85 / 85 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 85 / 85 |
| Cooling capacity · BTU/h | 52,500–54,500 | 85 / 85 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 50,000–53,500 | 85 / 85 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–51,000 | 85 / 85 |
| Heating capacity at 5°F / −15°C · BTU/h | 37,000–40,000 | 85 / 85 |
| COP at 5°F / −15°C | 1.6–1.84 | 85 / 85 |
| Equipment / loop type | HP - Split System | 85 / 85 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 85 / 85 |
| Compressor staging | Continuously variable | 85 / 85 |
| Connected capability | No | 85 / 85 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4PX*DU60BS3+ furnace: S8V2C100M5PDAAHRI reference: 211081284 | 18.00 | 8.00 | 39000 | 1.73 | EPA 2526608 → |
4TXCD010DS3+ furnace: S8V2C100M5PDAAHRI reference: 211081287 | 18.00 | 8.00 | 39000 | 1.73 | EPA 2526609 → |
4PX*DU60BS3+P0V0C000M50SC+RPAHRI reference: 207805633 | 18.00 | 8.10 | 38000 | 1.69 | EPA 2526639 → |
4TXCD010DS3+P0V0D000M50SC+RPAHRI reference: 207805637 | 18.00 | 8.20 | 39000 | 1.75 | EPA 2526640 → |
4PX*DU60BS3+P0V0D000M50SC+RPAHRI reference: 207805632 | 18.00 | 8.20 | 39000 | 1.75 | EPA 2526641 → |
TEM8B0C60V51+TDRAHRI reference: 207820957 | 18.00 | 8.50 | 37000 | 1.84 | EPA 2526642 → |
TEM8A0C48V41+TDRAHRI reference: 210636927 | 18.00 | 8.50 | 37000 | 1.84 | EPA 2526643 → |
TAMXB0C60V51AHRI reference: 210929573 | 18.00 | 8.20 | 39500 | 1.76 | EPA 2526645 → |
4PX*CU60BS3+ furnace: S8V2C100M5PCACold climate designationAHRI reference: 210691921 | 18.00 | 8.20 | 40000 | 1.78 | EPA 2527080 → |
4TXCD010DS3+ furnace: S8V2D120M5PCAAHRI reference: 210691927 | 18.00 | 8.20 | 39500 | 1.83 | EPA 2527081 → |
4PX*DU60BS3+ furnace: S8V2D120M5PCAAHRI reference: 210691923 | 18.00 | 8.20 | 39500 | 1.83 | EPA 2527082 → |
4TXCC009DS3+ furnace: S8V2C100M5PCACold climate designationAHRI reference: 210691925 | 18.00 | 8.20 | 40000 | 1.78 | EPA 2527084 → |
4TXCD010DS3+ furnace: S9V2D120U5VSA+RPAHRI reference: 207526499 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2527430 → |
4PX*DU60BS3+ furnace: S9V2D120U5VSA+RPAHRI reference: 207526497 | 18.00 | 8.20 | 39500 | 1.72 | EPA 2527434 → |
4PX*CU60BS3+ furnace: S8V2C100M5PDACold climate designationAHRI reference: 211081282 | 18.00 | 8.20 | 40000 | 1.78 | EPA 2527510 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDAAHRI reference: 211081285 | 18.00 | 8.20 | 39500 | 1.83 | EPA 2527511 → |
4TXCC009DS3+ furnace: S8V2C100M5PDACold climate designationAHRI reference: 211081286 | 18.00 | 8.20 | 40000 | 1.78 | EPA 2527512 → |
4TXCD010DS3+ furnace: S8V2D120M5PDAAHRI reference: 211081288 | 18.00 | 8.20 | 39500 | 1.83 | EPA 2527513 → |
4PX*CD60BS3+P0V0C000M50SC+RPAHRI reference: 207805627 | 18.00 | 8.00 | 39500 | 1.67 | EPA 2528254 → |
4PX*DD60BS3+P0V0D000M50SC+RPAHRI reference: 207805630 | 18.00 | 8.20 | 39500 | 1.71 | EPA 2528255 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →