4TWV7X60A1
XV17 · source records, page 3
58 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4TWV7X60A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 58 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–17.1 | 58 / 58 |
| EER2 · BTU/Wh | 11.7–12 | 58 / 58 |
| HSPF2 · BTU/Wh | 8–8.5 | 58 / 58 |
| Cooling capacity · BTU/h | 52,500–54,000 | 58 / 58 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 51,500–53,500 | 58 / 58 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 48,000–51,000 | 58 / 58 |
| Heating capacity at 5°F / −15°C · BTU/h | 38,000–40,000 | 58 / 58 |
| COP at 5°F / −15°C | 1.6–1.8 | 58 / 58 |
| Equipment / loop type | HP - Split System | 58 / 58 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 58 / 58 |
| Compressor staging | Continuously variable | 58 / 58 |
| Connected capability | No | 58 / 58 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4TXCD010DS3+ furnace: S9V2D120U5PSB+LRPAHRI reference: 213826805 | 17.10 | 8.20 | 38500 | 1.70 | EPA 2860902 → |
TEM8A0C48V41+TDR+LRPAHRI reference: 214671749 | 17.10 | 8.50 | 38000 | 1.80 | EPA 3491910 → |
TEM8B0C60V51+TDR+LRPAHRI reference: 214671756 | 17.10 | 8.50 | 38000 | 1.80 | EPA 3491912 → |
4PX*DU60BS3+ furnace: S8V2D120M5PCBAHRI reference: 214639901 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477159 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDBAHRI reference: 214639903 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477160 → |
4TXCD010DS3+ furnace: S8V2D120M5PCBAHRI reference: 214639917 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477164 → |
4TXCD010DS3+ furnace: S8V2D120M5PDBAHRI reference: 214639919 | 17.00 | 8.20 | 39000 | 1.70 | EPA 3477166 → |
4PX*DU60BS3+ furnace: S8V2C100M5PCBAHRI reference: 214639899 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477543 → |
4TXCD010DS3+ furnace: S8V2C100M5PCBAHRI reference: 214639913 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477551 → |
4TXCD010DS3+ furnace: S8V2C100M5PDBAHRI reference: 214639915 | 17.00 | 8.10 | 38000 | 1.60 | EPA 3477552 → |
4PX*CU60BS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825833 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799569 → |
4PX*CU60BS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825835 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799571 → |
4PX*DU60BS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825841 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799615 → |
4PX*DU60BS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825843 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799617 → |
4TXCC009DS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825845 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799622 → |
4TXCC009DS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825847 | 17.00 | 8.10 | 39500 | 1.72 | EPA 3799624 → |
4TXCD010DS3+ furnace: S9V2C100U5VSB+LRPAHRI reference: 215825849 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799626 → |
4TXCD010DS3+ furnace: S9V2C080U5VSB+LRPAHRI reference: 215825851 | 17.00 | 8.10 | 39500 | 1.73 | EPA 3799628 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →