4TWV7X48A1
XV17 · source records, page 5
129 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for 4TWV7X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 129 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 17–17.1 | 129 / 129 |
| EER2 · BTU/Wh | 11.7–12 | 129 / 129 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 129 / 129 |
| Cooling capacity · BTU/h | 44,000–47,000 | 129 / 129 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,000–48,000 | 129 / 129 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 35,200–37,600 | 129 / 129 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,400–28,800 | 129 / 129 |
| COP at 5°F / −15°C | 1.7–1.9 | 129 / 129 |
| Equipment / loop type | HP - Split System | 129 / 129 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 129 / 129 |
| Compressor staging | Continuously variable | 129 / 129 |
| Connected capability | No | 129 / 129 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4TXCC009DS3+ furnace: S9V2C100U5PSC+LRPAHRI reference: 213826685 | 17.10 | 8.50 | 28600 | 1.80 | EPA 2860914 → |
4TXCC007DS3+ furnace: *UHMC100CCV4+LRPAHRI reference: 213826677 | 17.10 | 8.50 | 28600 | 1.80 | EPA 2860916 → |
4TXCC009DS3+ furnace: L8V1C100U5VSB+LRPAHRI reference: 213826687 | 17.10 | 8.50 | 28400 | 1.80 | EPA 2860920 → |
4TXCD010DS3+ furnace: L8V1C100U5VSB+LRPAHRI reference: 213826713 | 17.10 | 8.50 | 27400 | 1.80 | EPA 2860921 → |
4TXCC009DS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 213826689 | 17.10 | 8.50 | 28400 | 1.80 | EPA 2860922 → |
4TXCD010DS3+ furnace: *UHMD120CCV5+LRPAHRI reference: 213826715 | 17.10 | 8.50 | 28200 | 1.80 | EPA 2860924 → |
4TXCD010DS3+ furnace: *UHMD120ACV5+LRPAHRI reference: 213826717 | 17.10 | 8.50 | 28200 | 1.80 | EPA 2860928 → |
4TXCD010DS3+ furnace: *UHMC100CCV4+LRPAHRI reference: 213826719 | 17.10 | 8.50 | 27400 | 1.80 | EPA 2860929 → |
TEM8A0C48V41+TDR+LRPAHRI reference: 214671738 | 17.10 | 8.50 | 28400 | 1.90 | EPA 3491907 → |
TEM8B0C60V51+TDR+LRPAHRI reference: 214671744 | 17.10 | 8.50 | 28400 | 1.90 | EPA 3491908 → |
4PX*DU60BS3+ furnace: S8V2C100M5PCBAHRI reference: 214639815 | 17.00 | 8.20 | 27600 | 1.80 | EPA 3476988 → |
4PX*DU60BS3+ furnace: S8V2C080M5PDBAHRI reference: 214639817 | 17.00 | 8.20 | 27400 | 1.80 | EPA 3476990 → |
4PX*DU60BS3+ furnace: S8V2C080M5PCBAHRI reference: 214639819 | 17.00 | 8.20 | 27400 | 1.80 | EPA 3476993 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDBAHRI reference: 214639821 | 17.00 | 8.20 | 28400 | 1.80 | EPA 3476995 → |
4TXCC009DS3+ furnace: S8V2C080M5PDBAHRI reference: 214639845 | 17.00 | 8.20 | 28400 | 1.80 | EPA 3476999 → |
4TXCC009DS3+ furnace: S8V2C080M5PCBAHRI reference: 214639847 | 17.00 | 8.20 | 28400 | 1.80 | EPA 3477001 → |
4TXCC009DS3+ furnace: S8V2C100M5PCBAHRI reference: 214639849 | 17.00 | 8.20 | 28600 | 1.80 | EPA 3477003 → |
4TXCC009DS3+ furnace: S8V2C100M5PDBAHRI reference: 214639851 | 17.00 | 8.20 | 28600 | 1.80 | EPA 3477005 → |
4TXCD008DS3+ furnace: S8V2D120M5PCBAHRI reference: 214639853 | 17.00 | 8.20 | 28800 | 1.80 | EPA 3477007 → |
4PX*CD60BS3+ furnace: S8V2C100M5PDBAHRI reference: 214639741 | 17.00 | 8.20 | 28600 | 1.70 | EPA 3477025 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →