Trane / AIR-SOURCE HEAT PUMP

4TWV7X48A1

XV17 · source records, page 3

129 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity44,000–47,000BTU/h

Each efficiency range summarizes published EPA records for 4TWV7X48A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 129 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.1129 / 129
EER2 · BTU/Wh11.7–12129 / 129
HSPF2 · BTU/Wh8.1–8.5129 / 129
Cooling capacity · BTU/h44,000–47,000129 / 129
Heating capacity at 47°F / 8.3°C · BTU/h40,000–48,000129 / 129
Heating capacity at 17°F / −8.3°C · BTU/h35,200–37,600129 / 129
Heating capacity at 5°F / −15°C · BTU/h27,400–28,800129 / 129
COP at 5°F / −15°C1.7–1.9129 / 129
Equipment / loop typeHP - Split System129 / 129
Refrigerant / source-reported GWPR-410A (GWP:2088)129 / 129
Compressor stagingContinuously variable129 / 129
Connected capabilityNo129 / 129

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*DU48BS3+ furnace: S9V2C100U5PSB+LRPAHRI reference: 21382664917.108.50280001.70EPA 2860583 →
4PX*DU60BS3+ furnace: S9V2C080U5PSB+LRPAHRI reference: 21382665517.108.50276001.80EPA 2860584 →
4PX*DU60BS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382665317.108.50276001.80EPA 2860585 →
4PX*DU60BS3+ furnace: L8V1C100U5VSB+LRPAHRI reference: 21382665717.108.50274001.80EPA 2860588 →
4PX*DU60BS3+ furnace: *UHMD120CCV5+LRPAHRI reference: 21382665917.108.50282001.80EPA 2860589 →
4PX*DU60BS3+ furnace: *UHMD120ACV5+LRPAHRI reference: 21382666117.108.50282001.80EPA 2860592 →
4PX*DU60BS3+ furnace: *UHMC100CCV4+LRPAHRI reference: 21382666317.108.50274001.80EPA 2860595 →
4TXCD010DS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382672517.108.50276001.80EPA 2860606 →
4TXCD010DS3+ furnace: S9V2C100U4VSA+LRPAHRI reference: 21382672717.108.50274001.80EPA 2860617 →
4TXCD010DS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 21382672917.108.50274001.80EPA 2860637 →
4TXCD010DS3+ furnace: S9V2C100U5PSB+LRPAHRI reference: 21382673117.108.50276001.80EPA 2860652 →
4TXCD010DS3+ furnace: *UHMC100ACV4+LRPAHRI reference: 21382673317.108.50274001.80EPA 2860662 →
4TXCC009DS3+ furnace: S9V2C100U4VSA+LRPAHRI reference: 21382669117.108.50284001.80EPA 2860802 →
4TXCC009DS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382669317.108.50286001.80EPA 2860806 →
4TXCC009DS3+ furnace: S9V2C100U5PSB+LRPAHRI reference: 21382669717.108.50286001.80EPA 2860811 →
4TXCD008DS3+ furnace: S9V2C100U5PSC+LRPAHRI reference: 21382669917.108.50280001.70EPA 2860813 →
4TXCD008DS3+ furnace: S9V2C100U5PSB+LRPAHRI reference: 21382670117.108.50280001.70EPA 2860814 →
4TXCC009DS3+ furnace: S9V2C080U5PSB+LRPAHRI reference: 21382669517.108.50286001.80EPA 2860818 →
4TXCD008DS3+ furnace: *UHMD120CCV5+LRPAHRI reference: 21382670517.108.50286001.80EPA 2860819 →
4TXCD008DS3+ furnace: L8V1C100U5VSB+LRPAHRI reference: 21382670317.108.50278001.70EPA 2860820 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →