Trane / AIR-SOURCE HEAT PUMP

4TWV7X36A1

XV17 · source records, page 4

144 published source records · source checked Sep 21, 2026

SEER2 range17–17.1BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity33,600–35,600BTU/h

Each efficiency range summarizes published EPA records for 4TWV7X36A1. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 144 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh17–17.1144 / 144
EER2 · BTU/Wh11.7–12144 / 144
HSPF2 · BTU/Wh7.8–8.5144 / 144
Cooling capacity · BTU/h33,600–35,600144 / 144
Heating capacity at 47°F / 8.3°C · BTU/h29,000–36,000144 / 144
Heating capacity at 17°F / −8.3°C · BTU/h25,200–26,800144 / 144
Heating capacity at 5°F / −15°C · BTU/h19,800–21,000144 / 144
COP at 5°F / −15°C1.6–1.9144 / 144
Equipment / loop typeHP - Split System144 / 144
Refrigerant / source-reported GWPR-410A (GWP:2088)144 / 144
Compressor stagingContinuously variable144 / 144
Connected capabilityNo144 / 144

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
4PX*CU36BS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382651717.108.20202001.80EPA 2860709 →
4PX*CU36BS3+ furnace: S9V2C080U5PSB+LRPAHRI reference: 21382651917.108.20202001.80EPA 2860710 →
4PX*CU36BS3+ furnace: *UHMC100CCV4+LRPAHRI reference: 21382652117.108.20202001.80EPA 2860711 →
4PX*CU42BS3+ furnace: S9V2C100U4VSB+LRPAHRI reference: 21382652317.108.50204001.80EPA 2860714 →
4PX*CU42BS3+ furnace: S9V2C100U4VSA+LRPAHRI reference: 21382652517.108.50204001.80EPA 2860715 →
4TXCB004DS3+ furnace: *UHMB060ACV3+LRPAHRI reference: 21382654517.108.20206001.70EPA 2860742 →
4TXCB004DS3+ furnace: *UHMB080ACV3+LRPAHRI reference: 21382654917.108.20204001.70EPA 2860746 →
4TXCB006DS3+ furnace: S9V2B040U3PSC+LRPAHRI reference: 21382655117.108.50210001.80EPA 2860747 →
4TXCB006DS3+ furnace: *UHMB060CCV3+LRPAHRI reference: 21382655317.108.50204001.80EPA 2860748 →
4TXCB006DS3+ furnace: S9V2B080U4VSB+LRPAHRI reference: 21382655717.108.50204001.80EPA 2860752 →
4TXCB004DS3+ furnace: *UHMB060CCV3+LRPAHRI reference: 21382654717.108.20206001.70EPA 2860753 →
4TXCB006DS3+ furnace: S9V2B080U4VSA+LRPAHRI reference: 21382655917.108.50204001.80EPA 2860756 →
4TXCB006DS3+ furnace: *UHMB060ACV3+LRPAHRI reference: 21382655517.108.50204001.80EPA 2860757 →
4TXCB006DS3+ furnace: S9V2B080U4PSC+LRPAHRI reference: 21382656117.108.50204001.80EPA 2860762 →
4TXCB006DS3+ furnace: S9V2B080U4PSB+LRPAHRI reference: 21382656317.108.50204001.80EPA 2860765 →
4TXCB006DS3+ furnace: S9V2B060U4PSC+LRPAHRI reference: 21382656517.108.50206001.80EPA 2860766 →
4TXCB006DS3+ furnace: S9V2B060U4PSB+LRPAHRI reference: 21382656717.108.50206001.80EPA 2860771 →
4PX*CD42BS3+ furnace: *DHMC100ACV4+LRPAHRI reference: 21382650317.108.00204001.70EPA 2860773 →
4PX*CD42BS3+ furnace: *DHMC100CCV4+LRPAHRI reference: 21382650517.108.00204001.70EPA 2860774 →
4PX*CU42BS3+ furnace: S9V2C080U5PSC+LRPAHRI reference: 21382652717.108.50204001.80EPA 2860777 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →