Heating performance & equipment details
Ranges include the 118 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 19–20 | 118 / 118 |
| EER2 · BTU/Wh | 11.5–12 | 118 / 118 |
| HSPF2 · BTU/Wh | 7.8–8.7 | 118 / 118 |
| Cooling capacity · BTU/h | 44,000–47,000 | 118 / 118 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 40,500–44,000 | 118 / 118 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 34,800–36,800 | 118 / 118 |
| Heating capacity at 5°F / −15°C · BTU/h | 27,000–28,600 | 118 / 118 |
| COP at 5°F / −15°C | 1.66–1.9 | 118 / 118 |
| Equipment / loop type | HP - Split System | 118 / 118 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 118 / 118 |
| Compressor staging | Continuously variable | 118 / 118 |
| Connected capability | No | 118 / 118 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
4PX*CU60BS3+ furnace: L8V1C100U5VSB+RPAHRI reference: 212629843 | 19.50 | 8.50 | 27800 | 1.80 | EPA 2632764 → |
4PX*DU60BS3+ furnace: *UHMC100CCV4AHRI reference: 214250685 | 19.50 | 8.20 | 27200 | 1.80 | EPA 3412792 → |
4PX*DU60BS3+ furnace: *UHMD120CCV5AHRI reference: 214250687 | 19.50 | 8.50 | 27800 | 1.80 | EPA 3412795 → |
4TXCC009DS3+ furnace: *UHMC100CCV4AHRI reference: 214250695 | 19.50 | 8.50 | 28200 | 1.90 | EPA 3412796 → |
4TXCD010DS3+ furnace: *UHMD120CCV5AHRI reference: 214250699 | 19.50 | 8.50 | 27800 | 1.80 | EPA 3412798 → |
4TXCD010DS3+ furnace: *UHMC100CCV4AHRI reference: 214250701 | 19.50 | 8.20 | 27200 | 1.80 | EPA 3412800 → |
4PX*DU60BS3+ furnace: S8V2D120M5PCBAHRI reference: 214253133 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3412932 → |
4PX*DU60BS3+ furnace: S8V2D120M5PDBAHRI reference: 214253135 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3412933 → |
4PX*CU60BS3+ furnace: *UHMC100CCV4AHRI reference: 214250679 | 19.50 | 8.50 | 28200 | 1.90 | EPA 3412956 → |
4TXCD010DS3+ furnace: S8V2D120M5PCBAHRI reference: 214253193 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3413035 → |
4TXCD010DS3+ furnace: S8V2D120M5PDBAHRI reference: 214253197 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3413039 → |
4PX*CD60BS3+ furnace: S9V2C100D5PSC+RPAHRI reference: 214639491 | 19.50 | 8.20 | 27800 | 1.70 | EPA 3477303 → |
4PX*CD60BS3+HORIZ-RT+ furnace: S9V2C100U5PSC+RPAHRI reference: 214639493 | 19.50 | 8.20 | 27800 | 1.70 | EPA 3477305 → |
4PX*CU60BS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 214639503 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3477306 → |
4PX*CU60BS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 214639505 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3477308 → |
4TXCC009DS3+ furnace: S9V2C100U5PSC+RPAHRI reference: 214639529 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3477312 → |
4TXCC009DS3+ furnace: S9V2C080U5PSC+RPAHRI reference: 214639531 | 19.50 | 8.50 | 28000 | 1.80 | EPA 3477314 → |
4PX*CD60BS3+ furnace: S9V2C100D5VSB+RPAHRI reference: 215825697 | 19.50 | 8.20 | 27800 | 1.74 | EPA 3799584 → |
4PX*CU60BS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 215825709 | 19.50 | 8.50 | 28000 | 1.81 | EPA 3799585 → |
4TXCC009DS3+ furnace: S9V2C100U5VSB+RPAHRI reference: 215825731 | 19.50 | 8.50 | 28000 | 1.81 | EPA 3799592 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.