Each efficiency range summarizes published EPA records for SP17AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 111 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 111 / 111 |
| EER2 · BTU/Wh | 9–11 | 111 / 111 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 111 / 111 |
| Cooling capacity · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–40,000 | 111 / 111 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,200–37,600 | 111 / 111 |
| COP at 5°F / −15°C | 2–2.1 | 111 / 111 |
| Equipment / loop type | HP - Split System | 111 / 111 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 111 / 111 |
| Compressor staging | Continuously variable | 111 / 111 |
| Connected capability | Yes | 111 / 111 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY4821STANM+ furnace: S801V0755A21UHSCold climate designationAHRI reference: 218327434 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620144 → |
TCFY4824STANM+ furnace: S801V0755A21UHNCold climate designationAHRI reference: 218327433 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620145 → |
TCFY4821STANM+ furnace: S801V0755A21UHNCold climate designationAHRI reference: 218327432 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620146 → |
TCFY4824STANM+ furnace: S801V0755A21DZSCold climate designationAHRI reference: 218327431 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620147 → |
TCFY4821STANM+ furnace: S801V0755A21DZSCold climate designationAHRI reference: 218327430 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620148 → |
TCFY4824STANM+ furnace: S801V0755A21DZNCold climate designationAHRI reference: 218327429 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620149 → |
TCFY4821STANM+ furnace: S801V0755A21DZNCold climate designationAHRI reference: 218327428 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620150 → |
TCFY4821STANM+ furnace: S801V0754A17UHSCold climate designationAHRI reference: 218327427 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620151 → |
TCFY4821STANM+ furnace: S801V0754A17UHNCold climate designationAHRI reference: 218327426 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620152 → |
TCFY4821STANM+ furnace: S801V0754A17DZSCold climate designationAHRI reference: 218327425 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4620153 → |
TCFY4821STANM+ furnace: S801V0754A17DZNCold climate designationAHRI reference: 218327424 | 16.00 | 9.50 | 37200 | 2.00 | EPA 4620154 → |
TCFY4821STANM+ furnace: S951V1005A21UHUCold climate designationAHRI reference: 218327520 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620965 → |
TCFY4824STANM+ furnace: S951V1005A21M4UCold climate designationAHRI reference: 218327519 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620966 → |
TCFY4821STANM+ furnace: S951V1005A21M4UCold climate designationAHRI reference: 218327518 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620967 → |
TCFY4824STANM+ furnace: S951V1005A21M4SCold climate designationAHRI reference: 218327517 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620968 → |
TCFY4821STANM+ furnace: S951V1005A21M4SCold climate designationAHRI reference: 218327516 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620969 → |
TCFY4824STANM+ furnace: S951V0855A21M4SCold climate designationAHRI reference: 218327515 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620970 → |
TCFY4821STANM+ furnace: S951V0855A21M4SCold climate designationAHRI reference: 218327514 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620971 → |
TCFY4824STANM+ furnace: S951V0705A21UHUCold climate designationAHRI reference: 218327513 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620972 → |
TCFY4821STANM+ furnace: S951V0705A21UHUCold climate designationAHRI reference: 218327512 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620973 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →