SP17AY48AJVC
NONE · VANTIX · source records, page 2
111 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for SP17AY48AJVC. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 111 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 111 / 111 |
| EER2 · BTU/Wh | 9–11 | 111 / 111 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 111 / 111 |
| Cooling capacity · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–45,500 | 111 / 111 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 39,000–40,000 | 111 / 111 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,200–37,600 | 111 / 111 |
| COP at 5°F / −15°C | 2–2.1 | 111 / 111 |
| Equipment / loop type | HP - Split System | 111 / 111 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 111 / 111 |
| Compressor staging | Continuously variable | 111 / 111 |
| Connected capability | Yes | 111 / 111 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
TCFY4824STANM+ furnace: S802V1255A24DZNCold climate designationAHRI reference: 218327478 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620124 → |
TCFY4824STANM+ furnace: S802V1005A21UHSCold climate designationAHRI reference: 218327477 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620125 → |
TCFY4821STANM+ furnace: S802V1005A21UHSCold climate designationAHRI reference: 218327476 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620126 → |
TCFY4824STANM+ furnace: S802V1005A21UHNCold climate designationAHRI reference: 218327475 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620127 → |
TCFY4821STANM+ furnace: S802V1005A21UHNCold climate designationAHRI reference: 218327474 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620128 → |
TCFY4824STANM+ furnace: S802V1005A21DZSCold climate designationAHRI reference: 218327473 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620129 → |
TCFY4824STANM+ furnace: S801V1255A24DZNCold climate designationAHRI reference: 218327448 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620130 → |
TCFY4824STANM+ furnace: S801V1005A21UHUCold climate designationAHRI reference: 218327447 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620131 → |
TCFY4821STANM+ furnace: S801V1005A21UHUCold climate designationAHRI reference: 218327446 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620132 → |
TCFY4824STANM+ furnace: S801V1005A21UHSCold climate designationAHRI reference: 218327445 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620133 → |
TCFY4821STANM+ furnace: S801V1005A21UHSCold climate designationAHRI reference: 218327444 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620134 → |
TCFY4824STANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 218327443 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620135 → |
TCFY4821STANM+ furnace: S801V1005A21UHNCold climate designationAHRI reference: 218327442 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620136 → |
TCFY4824STANM+ furnace: S801V1005A21DZSCold climate designationAHRI reference: 218327441 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620137 → |
TCFY4821STANM+ furnace: S801V1005A21DZSCold climate designationAHRI reference: 218327440 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620138 → |
TCFY4824STANM+ furnace: S801V1005A21DZNCold climate designationAHRI reference: 218327439 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620139 → |
TCFY4821STANM+ furnace: S801V1005A21DZNCold climate designationAHRI reference: 218327438 | 16.00 | 9.50 | 36600 | 2.00 | EPA 4620140 → |
TCFY4821STANM+ furnace: S801V1004A17UHSCold climate designationAHRI reference: 218327437 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620141 → |
TCFY4821STANM+ furnace: S801V1004A17UHNCold climate designationAHRI reference: 218327436 | 16.00 | 9.50 | 37000 | 2.00 | EPA 4620142 → |
TCFY4824STANM+ furnace: S801V0755A21UHSCold climate designationAHRI reference: 218327435 | 16.00 | 9.50 | 36800 | 2.00 | EPA 4620143 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →