D5CUHAH30AAK+KSAIC0701230
Crossover Heat Pump · source records, page 7
342 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for D5CUHAH30AAK+KSAIC0701230. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 342 / 342 |
| EER2 · BTU/Wh | 9.5–10.5 | 342 / 342 |
| HSPF2 · BTU/Wh | 8.1–9 | 342 / 342 |
| Cooling capacity · BTU/h | 28,600–31,200 | 342 / 342 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 342 / 342 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 342 / 342 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 342 / 342 |
| COP at 5°F / −15°C | 1.75–2 | 342 / 342 |
| Equipment / loop type | HP - Split System | 342 / 342 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 342 / 342 |
| Compressor staging | Continuously variable | 342 / 342 |
| Connected capability | No | 342 / 342 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X43M21A*+ furnace: *97VTN0601716A*Cold climate designationAHRI reference: 218681605 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672012 → |
EA*5X43M21A*+ furnace: *96VTN0801716B*Cold climate designationAHRI reference: 218681601 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672016 → |
EA*5X43M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218681600 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672017 → |
EA*5X43M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218681596 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672021 → |
EA*5X43M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218681595 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672022 → |
EA*5X43M21A*+ furnace: *95MSU0401712A*Cold climate designationAHRI reference: 218681594 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672023 → |
EA*5X43M21A*+ furnace: *96VSN0801716B*Cold climate designationAHRI reference: 218681591 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672026 → |
EA*5X43M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218681590 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672027 → |
EA*5X43M21A*+ furnace: *96MSN1002120A*Cold climate designationAHRI reference: 218681587 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672030 → |
EA*5X43M21A*+ furnace: *92MSN1002122A*Cold climate designationAHRI reference: 218681581 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672036 → |
EA*5X43M21A*+ furnace: *92MSN1002120A*Cold climate designationAHRI reference: 218681580 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672037 → |
EA*5X43M21A*+ furnace: *92MSN0802120A*Cold climate designationAHRI reference: 218681579 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672038 → |
EA*5X43M21A*+ furnace: *92MSN0801716A*Cold climate designationAHRI reference: 218681578 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672039 → |
EA*5X43M21A*+ furnace: *92MSN0601714A*Cold climate designationAHRI reference: 218681577 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672040 → |
EA*5X43M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218681575 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672042 → |
EA*5X43M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218681573 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672044 → |
EA*5X43M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218681568 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672049 → |
EA*5X43M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218681566 | 16.00 | 9.00 | 32200 | 1.96 | EPA 4672051 → |
EA*5X43M21A*+ furnace: *80MS(N,L)1102120A*Cold climate designationAHRI reference: 218681565 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672052 → |
EA*5X43M21A*+ furnace: *80MS(N,L)0902120A*Cold climate designationAHRI reference: 218681564 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672053 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →