Heating performance & equipment details
Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 342 / 342 |
| EER2 · BTU/Wh | 9.5–10.5 | 342 / 342 |
| HSPF2 · BTU/Wh | 8.1–9 | 342 / 342 |
| Cooling capacity · BTU/h | 28,600–31,200 | 342 / 342 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 35,800–37,400 | 342 / 342 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,800–21,600 | 342 / 342 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,000–33,400 | 342 / 342 |
| COP at 5°F / −15°C | 1.75–2 | 342 / 342 |
| Equipment / loop type | HP - Split System | 342 / 342 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 342 / 342 |
| Compressor staging | Continuously variable | 342 / 342 |
| Connected capability | No | 342 / 342 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
EA*5X42M21A*+ furnace: *96VTN1002122B*Cold climate designationAHRI reference: 218681660 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671961 → |
EA*5X42M21A*+ furnace: *96VTN0802120B*Cold climate designationAHRI reference: 218681658 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671963 → |
EA*5X42M21A*+ furnace: *96VTN0601716B*Cold climate designationAHRI reference: 218681656 | 16.00 | 8.50 | 33000 | 1.80 | EPA 4671965 → |
EA*5X42M21A*+ furnace: *95MSU1002122A*Cold climate designationAHRI reference: 218681654 | 16.00 | 8.50 | 32800 | 1.78 | EPA 4671966 → |
EA*5X42M21A*+ furnace: *95MSU1002120A*Cold climate designationAHRI reference: 218681653 | 16.00 | 8.50 | 33000 | 1.78 | EPA 4671967 → |
EA*5X42M21A*+ furnace: *95MSU0802120A*Cold climate designationAHRI reference: 218681652 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671968 → |
EA*5X42M21A*+ furnace: *95MSU0601716A*Cold climate designationAHRI reference: 218681651 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671969 → |
EA*5X42M21A*+ furnace: *96VSN0802120B*Cold climate designationAHRI reference: 218681648 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671972 → |
EA*5X42M21A*+ furnace: *96VSN0601716B*Cold climate designationAHRI reference: 218681646 | 16.00 | 8.50 | 33000 | 1.80 | EPA 4671974 → |
EA*5X42M21A*+ furnace: *80VTL1102122B*Cold climate designationAHRI reference: 218681632 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671987 → |
EA*5X42M21A*+ furnace: *80VTL0902120B*Cold climate designationAHRI reference: 218681631 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671988 → |
EA*5X42M21A*+ furnace: *80VTL0701716B*Cold climate designationAHRI reference: 218681630 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671989 → |
EA*5X42M21A*+ furnace: *80MSU1002120A*Cold climate designationAHRI reference: 218681629 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671990 → |
EA*5X42M21A*+ furnace: *80MSU0401712A*Cold climate designationAHRI reference: 218681626 | 16.00 | 8.50 | 32800 | 1.78 | EPA 4671993 → |
EA*5X42M21A*+ furnace: *80VSL1102122B*Cold climate designationAHRI reference: 218681625 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671994 → |
EA*5X42M21A*+ furnace: *80VSL0902120B*Cold climate designationAHRI reference: 218681624 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671995 → |
EA*5X42M21A*+ furnace: *80VSL0901716B*Cold climate designationAHRI reference: 218681623 | 16.00 | 8.50 | 33000 | 1.80 | EPA 4671996 → |
EA*5X42M21A*+ furnace: *80VSL0701716B*Cold climate designationAHRI reference: 218681622 | 16.00 | 8.50 | 32800 | 1.80 | EPA 4671997 → |
EA*5X43M21A*+ furnace: OMV112K14ACold climate designationAHRI reference: 218681613 | 16.00 | 9.00 | 32200 | 2.00 | EPA 4672006 → |
EA*5X43M21A*+ furnace: *97VTN0801716A*Cold climate designationAHRI reference: 218681606 | 16.00 | 9.00 | 32200 | 1.98 | EPA 4672011 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.