ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L30P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 7

135 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.2BTU/Wh
HSPF2 range7.8–8.6BTU/Wh
Cooling capacity28,200–30,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L30P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 135 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.2135 / 135
EER2 · BTU/Wh12.2–13.5135 / 135
HSPF2 · BTU/Wh7.8–8.6135 / 135
Cooling capacity · BTU/h28,200–30,000135 / 135
Heating capacity at 47°F / 8.3°C · BTU/h27,200–30,000135 / 135
Heating capacity at 17°F / −8.3°C · BTU/h17,400–19,600135 / 135
Heating capacity at 5°F / −15°C · BTU/h13,400–15,400135 / 135
COP at 5°F / −15°C1.96–2.36135 / 135
Equipment / loop typeHP - Split System135 / 135
Refrigerant / source-reported GWPR-410A (GWP:2088)135 / 135
Compressor stagingSingle stage135 / 135
Connected capabilityNo135 / 135

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032707415.407.80143002.18EPA 2457223
EAC4X30B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032716715.407.80143002.18EPA 2458729
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032716615.407.80143002.18EPA 2458738
EAC4X30B+TDR+ furnace: 96G1UH030BE08AHRI reference: 21032717415.407.80144002.20EPA 2458908
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032707315.407.80143002.18EPA 2459043
BCE5V30M*4XAHRI reference: 21032705515.408.10139002.16EPA 2459595
EAH1P36C*+TDR+TXV+ furnace: 95G1UH080CE16XAHRI reference: 21173592615.408.30145002.22EPA 2466644
EAH1P36C*+TDR+TXV+ furnace: 95G1UH100CE20XAHRI reference: 21173593615.408.50148002.24EPA 2467959
EAD4X-42B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326537315.408.60154002.30EPA 2839886
7EC30BX-0*+TDR+ furnace: 97G2UH045BV12AHRI reference: 21483164115.408.00145002.16EPA 3544448
EA(C;U)1P30B+TDR+TXV+ furnace: 80G1UH080BE16XAHRI reference: 21032707015.208.00147002.16EPA 2457417
EAC4X30B+TDR+ furnace: 80G1UH080BE16XAHRI reference: 21032716215.208.00147002.16EPA 2458131
EAH1P30A*+TDR+TXV+ furnace: 80G1UH060AE12XAHRI reference: 21173579515.207.80141001.96EPA 2468393
EAH1P30A*+TDR+TXV+ furnace: 80G1UH040AE12XAHRI reference: 21173578315.207.80141001.96EPA 2468401
7EH36CX-0*+TDR+ furnace: 97G2UH110CV20AHRI reference: 21483165015.208.50152002.22EPA 3544451

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →