ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 7

145 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 145 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17145 / 145
EER2 · BTU/Wh12.5–14145 / 145
HSPF2 · BTU/Wh7.8–8.2145 / 145
Cooling capacity · BTU/h22,400–24,000145 / 145
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600145 / 145
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700145 / 145
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500145 / 145
COP at 5°F / −15°C2–2.18145 / 145
Equipment / loop typeHP - Split System145 / 145
Refrigerant / source-reported GWPR-410A (GWP:2088)145 / 145
Compressor stagingSingle stage145 / 145
Connected capabilityNo145 / 145

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12AHRI reference: 21032724115.807.80106002.04EPA 2836818
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032724815.807.80106002.00EPA 2836820
EA(C;U)1P24B+TDR+TXV+ furnace: 92G1UH045BE12AHRI reference: 21032722015.807.80106002.00EPA 2836821
EA(C;U)1P30A+TDR+TXV+ furnace: 80G2UH070AE12LAHRI reference: 21032724215.807.80106002.04EPA 2836874
BCE7E30M*4XAHRI reference: 21185562015.608.10108002.16EPA 2471012
EAC4X30B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032735715.607.80106002.00EPA 2471368
EAC4X30B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032735915.607.80106002.00EPA 2471441
EAC4X30B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032735615.607.80106002.00EPA 2471537
EAC4X24B+TDR+ furnace: 96G1UH045BE12AHRI reference: 21032732815.607.80108002.00EPA 2471540
EAC4X24B+TDR+ furnace: 95G1UH060BE12XAHRI reference: 21032733115.607.80108002.00EPA 2471542
EAC4X24B+TDR+ furnace: 96G1UH070BE12AHRI reference: 21032732915.607.80108002.00EPA 2471731
EAC4X24B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032733015.607.80108002.00EPA 2471732
EAC4X30B+TDR+ furnace: 95G1UH040BE12XAHRI reference: 21032735815.607.80106002.00EPA 2471776
EAD4X-30/36B+TDR+ furnace: 96G1DF045BE12AHRI reference: 21326536015.608.20114002.08EPA 2648756
EAD4X-30/36C+TDR+ furnace: 80G1DF110CE20AHRI reference: 21326536315.608.20114002.08EPA 2648813
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH040BE12XAHRI reference: 21032725315.607.80106002.00EPA 2836724
EA(C;U)1P24B+TDR+TXV+ furnace: 96G1UH045BE12AHRI reference: 21032722315.607.80108002.00EPA 2836786
EA(C;U)1P24B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032722615.607.80108002.00EPA 2836787
EA(C;U)1P30B+TDR+TXV+ furnace: 96G1UH070BE12AHRI reference: 21032725215.607.80106002.00EPA 2836802
EA(C;U)1P30B+TDR+TXV+ furnace: 95G1UH060BE12XAHRI reference: 21032725415.607.80106002.00EPA 2836826

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →