ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L24P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 3

145 published source records · source checked Sep 21, 2026

SEER2 range15.4–17BTU/Wh
HSPF2 range7.8–8.2BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L24P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 145 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.4–17145 / 145
EER2 · BTU/Wh12.5–14145 / 145
HSPF2 · BTU/Wh7.8–8.2145 / 145
Cooling capacity · BTU/h22,400–24,000145 / 145
Heating capacity at 47°F / 8.3°C · BTU/h21,000–22,600145 / 145
Heating capacity at 17°F / −8.3°C · BTU/h13,400–14,700145 / 145
Heating capacity at 5°F / −15°C · BTU/h10,200–11,500145 / 145
COP at 5°F / −15°C2–2.18145 / 145
Equipment / loop typeHP - Split System145 / 145
Refrigerant / source-reported GWPR-410A (GWP:2088)145 / 145
Compressor stagingSingle stage145 / 145
Connected capabilityNo145 / 145

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA(C;U)1P24B+TDR+TXV+ furnace: 80G1UH090BE16AHRI reference: 21032723316.407.80104002.08EPA 2837222
EAH1P30B*+TDR+TXV+ furnace: 96G1UH030BE08AHRI reference: 21173528916.407.80102002.02EPA 2837343
EAH1P30B*+TDR+TXV+ furnace: 92G1UH030BE12AHRI reference: 21173524516.407.80102002.04EPA 2837358
7EC24BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21483163016.407.80104002.04EPA 3544445
7EC30BX-0*+TDR+ furnace: 97G2UH070BV12AHRI reference: 21483163416.407.80104002.06EPA 3544460
EAH1P30B*+TDR+TXV+ furnace: 80G2UH090BV16AHRI reference: 21173534616.407.80104002.04EPA 3990367
EAC4X30B+TDR+ furnace: 92G1UH070BE12AHRI reference: 21032735416.207.80106002.04EPA 2471379
EAC4X30B+TDR+ furnace: 92G1UH030BE12AHRI reference: 21032735216.207.80102002.00EPA 2471436
EAC4X30A+TDR+ furnace: 80G1UH045AE12AHRI reference: 21032734216.207.80102002.02EPA 2471532
EAH1P24A*+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21173500716.207.80106002.08EPA 2471613
EAC4X30A+TDR+ furnace: 80G1UH070AE12LAHRI reference: 21032734416.207.80104002.04EPA 2471627
EAC4X30A+TDR+ furnace: 80G1UH070AE12AHRI reference: 21032734316.207.80104002.04EPA 2471630
EAH1P24A*+TDR+TXV+ furnace: 80G1UH045AE12AHRI reference: 21173496716.207.80102002.04EPA 2471919
EAD4X-30/36B+TDR+ furnace: 80G1DF090BE16AHRI reference: 21326535716.208.20112002.12EPA 2648792
EAD4X-30/36C+TDR+ furnace: 92G1DF090CE16AHRI reference: 21326536416.208.20110002.08EPA 2648812
EA(C;U)1P30B+TDR+TXV+ furnace: 92G1UH070BE12AHRI reference: 21032724916.207.80106002.04EPA 2836736
EA(C;U)1P24A+TDR+TXV+ furnace: 80G2UH070AV12AHRI reference: 21032721716.207.80104002.04EPA 2836782
EA(C;U)1P24A+TDR+TXV+ furnace: 80G1UH070AE12AHRI reference: 21032720916.207.80104002.02EPA 2836788
EAC4X24A+TDR+ furnace: 80G2UH070AV12AHRI reference: 21032732216.207.80104002.04EPA 2836790
EA(C;U)1P30A+TDR+TXV+ furnace: 80G1UH070AE12LAHRI reference: 21032723916.207.80104002.04EPA 2836791

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →