ROYALTON / AIR-SOURCE HEAT PUMP

4HP17L18P-**A

4HP17 SERIES · 4HP17 Series · 4HP17L SERIES · 4HP17L Series · source records, page 8

145 published source records · source checked Sep 21, 2026

SEER2 range15.2–16.8BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for 4HP17L18P-**A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 145 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16.8145 / 145
EER2 · BTU/Wh12.2–14145 / 145
HSPF2 · BTU/Wh7.8–8.5145 / 145
Cooling capacity · BTU/h18,000145 / 145
Heating capacity at 47°F / 8.3°C · BTU/h16,800–18,000145 / 145
Heating capacity at 17°F / −8.3°C · BTU/h10,200–12,100145 / 145
Heating capacity at 5°F / −15°C · BTU/h7,500–9,700145 / 145
COP at 5°F / −15°C1.9–2.16145 / 145
Equipment / loop typeHP - Split System145 / 145
Refrigerant / source-reported GWPR-410A (GWP:2088)145 / 145
Compressor stagingSingle stage145 / 145
Connected capabilityNo145 / 145

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EAC4X30B+TDR+ furnace: 80G2UH090BE16AHRI reference: 21032753415.207.8081001.90EPA 2458740
EAC4X30B+TDR+ furnace: 80G1UH090BE16AHRI reference: 21032753215.207.8081001.94EPA 2458761
EAC4X30B+TDR+ furnace: 80G2UH090BE16LAHRI reference: 21032753515.207.8081001.90EPA 2459311
EA(C;U)1P30B+TDR+TXV+ furnace: 80G2UH090BE16LAHRI reference: 21032742215.207.8081001.90EPA 2459721
BCE5C18M*4XAHRI reference: 21032466915.208.0085002.02EPA 2461613

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →