| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 78 / 78 |
| EER2 · BTU/Wh | 9.8–12 | 78 / 78 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 78 / 78 |
| Cooling capacity · BTU/h | 44,000–48,000 | 78 / 78 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–50,000 | 78 / 78 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–39,500 | 78 / 78 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–48,000 | 78 / 78 |
| COP at 5°F / −15°C | 1.75–2 | 78 / 78 |
| Equipment / loop type | HP - Split System | 78 / 78 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 78 / 78 |
| Compressor staging | Continuously variable | 78 / 78 |
| Connected capability | No | 78 / 78 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H60B-CA-UC+ furnace: RG19100C20MPS1Cold climate designationAHRI reference: 218156218 | 15.80 | 8.30 | 42000 | 1.80 | EPA 4576057 → |
MAAHE-H60B-CA+ furnace: RG19100C20MPS1Cold climate designationAHRI reference: 218155460 | 15.80 | 8.30 | 42000 | 1.80 | EPA 4576407 → |
MAAHE-H60B-CA-UC+ furnace: ML196UH090XE60C*Cold climate designationAHRI reference: 218156498 | 15.50 | 8.30 | 42000 | 1.80 | EPA 4575949 → |
MAAHE-H60B-CA-UC+ furnace: MGV96U100C5CCold climate designationAHRI reference: 218155884 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4576184 → |
MAAHE-H60B-CA+ furnace: ML196UH090XE60C*Cold climate designationAHRI reference: 218155740 | 15.50 | 8.30 | 42000 | 1.80 | EPA 4576299 → |
MAAHE-H60B-CA+ furnace: MGV96U100C5CCold climate designationAHRI reference: 218155136 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4576534 → |
MAAHE-H60B-CA-UC+ furnace: BZ33-96E2U100C5Cold climate designationAHRI reference: 218396922 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4599640 → |
MAAHE-H60B-CA+ furnace: BZ33-96E2U100C5Cold climate designationAHRI reference: 218396886 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4599676 → |
MAAHE-H60B-CA-UC+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466434 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4624696 → |
MAAHE-H60B-CA+ furnace: W962V100CU5SAACold climate designationAHRI reference: 218466329 | 15.50 | 8.30 | 41000 | 1.75 | EPA 4624734 → |
MAAHE-H60B-CA-UC+ furnace: ML193UH110XE60C*Cold climate designationAHRI reference: 218156496 | 15.40 | 8.40 | 42000 | 1.80 | EPA 4575951 → |
MAAHE-H60B-DA-UC+ furnace: RL18130D20MPS1Cold climate designationAHRI reference: 218156270 | 15.40 | 8.20 | 42000 | 1.80 | EPA 4576023 → |
MAAHE-H60B-CA-UC+ furnace: RG19100C16MPS1Cold climate designationAHRI reference: 218156217 | 15.40 | 8.20 | 42000 | 1.80 | EPA 4576058 → |
MAAHE-H60B-CA+ furnace: ML193UH110XE60C*Cold climate designationAHRI reference: 218155738 | 15.40 | 8.40 | 42000 | 1.80 | EPA 4576301 → |
MAAHE-H60B-DA+ furnace: RL18130D20MPS1Cold climate designationAHRI reference: 218155512 | 15.40 | 8.20 | 42000 | 1.80 | EPA 4576373 → |
MAAHE-H60B-CA+ furnace: RG19100C16MPS1Cold climate designationAHRI reference: 218155459 | 15.40 | 8.20 | 42000 | 1.80 | EPA 4576408 → |
MAAHE-H60B-CA-UC+ furnace: W801V100CM5SGACold climate designationAHRI reference: 218741662 | 15.40 | 8.50 | 42000 | 1.80 | EPA 4695912 → |
MAAHE-H60B-CA+ furnace: W801V100CM5SGACold climate designationAHRI reference: 218741630 | 15.40 | 8.50 | 42000 | 1.80 | EPA 4695927 → |
MAAHE-H60B-CA-UC+ furnace: MGV80M100C5NBCold climate designationAHRI reference: 218741598 | 15.40 | 8.50 | 42000 | 1.80 | EPA 4695942 → |
MAAHE-H60B-CA+ furnace: MGV80M100C5NBCold climate designationAHRI reference: 218741566 | 15.40 | 8.50 | 42000 | 1.80 | EPA 4695957 → |