MO1HE-H48B-2A
MAU Series · MO1 Series · source records, page 2
78 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MO1HE-H48B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 78 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17.5 | 78 / 78 |
| EER2 · BTU/Wh | 9.8–12 | 78 / 78 |
| HSPF2 · BTU/Wh | 8.1–9.5 | 78 / 78 |
| Cooling capacity · BTU/h | 44,000–48,000 | 78 / 78 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–50,000 | 78 / 78 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–39,500 | 78 / 78 |
| Heating capacity at 5°F / −15°C · BTU/h | 41,000–48,000 | 78 / 78 |
| COP at 5°F / −15°C | 1.75–2 | 78 / 78 |
| Equipment / loop type | HP - Split System | 78 / 78 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 78 / 78 |
| Compressor staging | Continuously variable | 78 / 78 |
| Connected capability | No | 78 / 78 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H60B-CA+ furnace: ML193UH110XE48C*Cold climate designationAHRI reference: 218155823 | 16.30 | 8.10 | 41000 | 1.80 | EPA 4576228 → |
MAAHE-H60B-CA+ furnace: ML193UH110XE48B*Cold climate designationAHRI reference: 218155737 | 16.30 | 8.10 | 41000 | 1.80 | EPA 4576302 → |
MAAHE-H60B-CA-UC+ furnace: ML193UH090XE48C*Cold climate designationAHRI reference: 218156578 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4575880 → |
MAAHE-H60B-CA-UC+ furnace: ML193UH090XE48B*Cold climate designationAHRI reference: 218156494 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4575953 → |
MAAHE-H60B-CA-UC+ furnace: RL18100C20MPS1Cold climate designationAHRI reference: 218156269 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576024 → |
MAAHE-H60B-CA-UC+ furnace: RL18100C16MPS1Cold climate designationAHRI reference: 218156268 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576025 → |
MAAHE-H60B-DA-UC+ furnace: S9V2D120U5VS***Cold climate designationAHRI reference: 218156082 | 16.10 | 8.50 | 41000 | 1.80 | EPA 4576103 → |
MAAHE-H60B-DA-UC+ furnace: S9V2D120D5VS***Cold climate designationAHRI reference: 218156081 | 16.10 | 8.50 | 41000 | 1.80 | EPA 4576104 → |
MAAHE-H60B-CA+ furnace: ML193UH090XE48C*Cold climate designationAHRI reference: 218155820 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576230 → |
MAAHE-H60B-CA+ furnace: ML193UH090XE48B*Cold climate designationAHRI reference: 218155736 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576303 → |
MAAHE-H60B-CA+ furnace: RL18100C20MPS1Cold climate designationAHRI reference: 218155511 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576374 → |
MAAHE-H60B-CA+ furnace: RL18100C16MPS1Cold climate designationAHRI reference: 218155510 | 16.10 | 8.20 | 42000 | 1.80 | EPA 4576375 → |
MAAHE-H60B-DA+ furnace: S9V2D120U5VS***Cold climate designationAHRI reference: 218155324 | 16.10 | 8.50 | 41000 | 1.80 | EPA 4576453 → |
MAAHE-H60B-DA+ furnace: S9V2D120D5VS***Cold climate designationAHRI reference: 218155323 | 16.10 | 8.50 | 41000 | 1.80 | EPA 4576454 → |
MAAHE-H60B-CA-UC+ furnace: ML296UH090XV48C*Cold climate designationAHRI reference: 218156588 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4575874 → |
MAAHE-H60B-CA-UC+ furnace: ML296UH090XV48B*Cold climate designationAHRI reference: 218156501 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4575946 → |
MAAHE-H60B-CA+ furnace: ML296UH090XV48C*Cold climate designationAHRI reference: 218155830 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4576224 → |
MAAHE-H60B-CA+ furnace: ML296UH090XV48B*Cold climate designationAHRI reference: 218155743 | 16.00 | 8.10 | 41000 | 1.80 | EPA 4576296 → |
MAAHE-H60B-CA-UC+ furnace: ML296DF090XV60C*Cold climate designationAHRI reference: 218156500 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4575947 → |
MAAHE-H60B-CA+ furnace: ML296DF090XV60C*Cold climate designationAHRI reference: 218155742 | 15.90 | 8.10 | 41000 | 1.80 | EPA 4576297 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →