| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 120 / 120 |
| EER2 · BTU/Wh | 10.8–12.5 | 120 / 120 |
| HSPF2 · BTU/Wh | 8.9–10.8 | 120 / 120 |
| Cooling capacity · BTU/h | 18,000 | 120 / 120 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–19,000 | 120 / 120 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,000–15,300 | 120 / 120 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–19,600 | 120 / 120 |
| COP at 5°F / −15°C | 1.7–2.12 | 120 / 120 |
| Equipment / loop type | HP - Split System | 120 / 120 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 120 / 120 |
| Compressor staging | Continuously variable | 120 / 120 |
| Connected capability | No | 120 / 120 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H24B-BA-UC+ furnace: MGV80M080B4ACold climate designationAHRI reference: 218155938 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4576159 → |
MAAHE-H24B-BA+ furnace: S9X2B040U3PSB**Cold climate designationAHRI reference: 218155351 | 15.30 | 9.30 | 18000 | 1.80 | EPA 4576442 → |
MAAHE-H24B-BA+ furnace: S9X1B040U3PSB**Cold climate designationAHRI reference: 218155237 | 15.30 | 9.30 | 18000 | 1.80 | EPA 4576490 → |
MAAHE-H24B-BA+ furnace: MGV80M080B4ACold climate designationAHRI reference: 218155180 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4576509 → |
MAAHE-H24B-BA-UC+ furnace: BZ33-80EM080B4Cold climate designationAHRI reference: 218396951 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4599611 → |
MAAHE-H24B-BA+ furnace: BZ33-80EM080B4Cold climate designationAHRI reference: 218396915 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4599647 → |
MAAHE-H24B-BA-UC+ furnace: W801V080BM4SFACold climate designationAHRI reference: 218466620 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4624642 → |
MAAHE-H24B-BA+ furnace: W801V080BM4SFACold climate designationAHRI reference: 218466569 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4624654 → |
MAAHE-H24B-BA-UC+ furnace: W801V080BM4SEBCold climate designationAHRI reference: 218466505 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4624666 → |
MAAHE-H24B-BA+ furnace: W801V080BM4SEBCold climate designationAHRI reference: 218466416 | 15.30 | 9.60 | 18000 | 1.80 | EPA 4624704 → |
MAAHE-H24B-BA-UC+ furnace: ML196DF070XE48B*Cold climate designationAHRI reference: 218156440 | 15.20 | 9.50 | 18000 | 1.80 | EPA 4576007 → |
MAAHE-H24B-BA-UC+ furnace: S9X2B060D3PSB**Cold climate designationAHRI reference: 218156110 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4576091 → |
MAAHE-H24B-BA-UC+ furnace: S9X1B060D3PSB**Cold climate designationAHRI reference: 218155996 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4576139 → |
MAAHE-H24B-BA+ furnace: ML196DF070XE48B*Cold climate designationAHRI reference: 218155682 | 15.20 | 9.50 | 18000 | 1.80 | EPA 4576357 → |
MAAHE-H24B-BA+ furnace: S9X2B060D3PSB**Cold climate designationAHRI reference: 218155352 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4576441 → |
MAAHE-H24B-BA+ furnace: S9X1B060D3PSB**Cold climate designationAHRI reference: 218155238 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4576489 → |
MAAHE-H24B-BA-UC+ furnace: W801V080BM4SGACold climate designationAHRI reference: 218741641 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4695924 → |
MAAHE-H24B-BA+ furnace: W801V080BM4SGACold climate designationAHRI reference: 218741609 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4695939 → |
MAAHE-H24B-BA-UC+ furnace: MGV80M080B4NBCold climate designationAHRI reference: 218741577 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4695954 → |
MAAHE-H24B-BA+ furnace: MGV80M080B4NBCold climate designationAHRI reference: 218741545 | 15.20 | 9.30 | 18000 | 1.80 | EPA 4695969 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.