Midea / AIR-SOURCE HEAT PUMP

MO1HE-H18B-2A

MAU Series · MO1 Series · source records, page 5

120 published source records · source checked Sep 21, 2026

SEER2 range15.2–19.3BTU/Wh
HSPF2 range8.9–10.8BTU/Wh
Cooling capacity18,000BTU/h

Each efficiency range summarizes published EPA records for MO1HE-H18B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 120 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19.3120 / 120
EER2 · BTU/Wh10.8–12.5120 / 120
HSPF2 · BTU/Wh8.9–10.8120 / 120
Cooling capacity · BTU/h18,000120 / 120
Heating capacity at 47°F / 8.3°C · BTU/h18,000–19,000120 / 120
Heating capacity at 17°F / −8.3°C · BTU/h13,000–15,300120 / 120
Heating capacity at 5°F / −15°C · BTU/h17,000–19,600120 / 120
COP at 5°F / −15°C1.7–2.12120 / 120
Equipment / loop typeHP - Split System120 / 120
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)120 / 120
Compressor stagingContinuously variable120 / 120
Connected capabilityNo120 / 120

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
MAAHE-H24B-AA-UCCold climate designationAHRI reference: 21749764216.109.50180002.06EPA 4438002 →
MAAHE-H24B-BA-UCCold climate designationAHRI reference: 21749764416.109.50180002.06EPA 4438004 →
MAAHE-H24B-BA+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21760852216.1010.00180001.90EPA 4480508 →
MAAHE-H24B-BA-UC+ furnace: MGV96U080B3CCold climate designationAHRI reference: 21815587316.1010.00180001.90EPA 4576195 →
MAAHE-H24B-BA-UC+ furnace: BZ33-96E2U080B3Cold climate designationAHRI reference: 21839693316.1010.00180001.90EPA 4599629 →
MAAHE-H24B-BA+ furnace: BZ33-96E2U080B3Cold climate designationAHRI reference: 21839690616.1010.00180001.90EPA 4599656 →
MAAHE-H24B-BA-UC+ furnace: W962V080BU3SAACold climate designationAHRI reference: 21846644716.1010.00180001.90EPA 4624685 →
MAAHE-H24B-BA+ furnace: W962V080BU3SAACold climate designationAHRI reference: 21846636816.1010.00180001.90EPA 4624715 →
MAAHE-H24B-BA-UC+ furnace: ML193UH030XE36B*AHRI reference: 21815643116.008.90170001.70EPA 4576016 →
MAAHE-H24B-BA+ furnace: ML193UH030XE36B*AHRI reference: 21815567316.008.90170001.70EPA 4576366 →
MAAHE-H24B-BA-UC+ furnace: ML196UH070XE36B*Cold climate designationAHRI reference: 21815644315.909.60180001.80EPA 4576004 →
MAAHE-H24B-BA+ furnace: ML196UH070XE36B*Cold climate designationAHRI reference: 21815568515.909.60180001.80EPA 4576354 →
MAAHE-H24B-BA+ furnace: RG19060B12MPS1Cold climate designationAHRI reference: 21760855815.8010.10190001.80EPA 4480516 →
MAAHE-H24B-BA-UC+ furnace: RG19060B12MPS1Cold climate designationAHRI reference: 21815585715.8010.10190001.80EPA 4576211 →
MAAHE-H24B-BA-UC+ furnace: ML196DF045XE36B*Cold climate designationAHRI reference: 21815643915.609.30180001.80EPA 4576008 →
MAAHE-H24B-BA+ furnace: ML196DF045XE36B*Cold climate designationAHRI reference: 21815568115.609.30180001.80EPA 4576358 →
MAAHE-H24B-BA-UC+ furnace: ML196UH045XE36B*Cold climate designationAHRI reference: 21815644215.509.30180001.80EPA 4576005 →
MAAHE-H24B-BA+ furnace: ML196UH045XE36B*Cold climate designationAHRI reference: 21815568415.509.30180001.80EPA 4576355 →
MAAHE-H24B-BA-UC+ furnace: S9X2B040U3PSB**Cold climate designationAHRI reference: 21815610915.309.30180001.80EPA 4576092 →
MAAHE-H24B-BA-UC+ furnace: S9X1B040U3PSB**Cold climate designationAHRI reference: 21815599515.309.30180001.80EPA 4576140 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.