Heating performance & equipment details
Ranges include the 120 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 120 / 120 |
| EER2 · BTU/Wh | 10.8–12.5 | 120 / 120 |
| HSPF2 · BTU/Wh | 8.9–10.8 | 120 / 120 |
| Cooling capacity · BTU/h | 18,000 | 120 / 120 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–19,000 | 120 / 120 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,000–15,300 | 120 / 120 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–19,600 | 120 / 120 |
| COP at 5°F / −15°C | 1.7–2.12 | 120 / 120 |
| Equipment / loop type | HP - Split System | 120 / 120 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 120 / 120 |
| Compressor staging | Continuously variable | 120 / 120 |
| Connected capability | No | 120 / 120 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H24B-BA+ furnace: ML193UH070XE36B*Cold climate designationAHRI reference: 218155675 | 16.80 | 9.70 | 18000 | 1.80 | EPA 4576364 → |
MAAHE-H24B-AA+ furnace: C30-2-VCold climate designationAHRI reference: 218155147 | 16.80 | 9.10 | 18000 | 1.80 | EPA 4576524 → |
MAAHE-H24B-AA-UC+ furnace: MGV80M060A3ACold climate designationAHRI reference: 218155936 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4576160 → |
MAAHE-H24B-AA+ furnace: MGV80M060A3ACold climate designationAHRI reference: 218155178 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4576510 → |
MAAHE-H24B-AA-UC+ furnace: W801V060AM3SFACold climate designationAHRI reference: 218466623 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4624641 → |
MAAHE-H24B-AA+ furnace: W801V060AM3SFACold climate designationAHRI reference: 218466571 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4624653 → |
MAAHE-H24B-AA-UC+ furnace: W801V060AM3SEBCold climate designationAHRI reference: 218466507 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4624665 → |
MAAHE-H24B-AA+ furnace: W801V060AM3SEBCold climate designationAHRI reference: 218466419 | 16.70 | 9.40 | 18000 | 1.80 | EPA 4624703 → |
MAAHE-H24B-BA-UC+ furnace: S9X2B040D3PSB**Cold climate designationAHRI reference: 218156108 | 16.60 | 9.50 | 18000 | 1.80 | EPA 4576093 → |
MAAHE-H24B-BA-UC+ furnace: S9X1B040D3PSB**Cold climate designationAHRI reference: 218155994 | 16.60 | 9.50 | 18000 | 1.80 | EPA 4576141 → |
MAAHE-H24B-AA-UC+ furnace: C45-2-VCold climate designationAHRI reference: 218155927 | 16.60 | 9.50 | 19000 | 1.90 | EPA 4576162 → |
MAAHE-H24B-BA+ furnace: S9X2B040D3PSB**Cold climate designationAHRI reference: 218155350 | 16.60 | 9.50 | 18000 | 1.80 | EPA 4576443 → |
MAAHE-H24B-BA+ furnace: S9X1B040D3PSB**Cold climate designationAHRI reference: 218155236 | 16.60 | 9.50 | 18000 | 1.80 | EPA 4576491 → |
MAAHE-H24B-AA+ furnace: C45-2-VCold climate designationAHRI reference: 218155169 | 16.60 | 9.50 | 19000 | 1.90 | EPA 4576512 → |
MAAHE-H24B-BA-UC+ furnace: RL18080B12MPS1Cold climate designationAHRI reference: 218156233 | 16.50 | 9.90 | 19000 | 1.90 | EPA 4576047 → |
MAAHE-H24B-AA-UC+ furnace: RL18040A12MPS1Cold climate designationAHRI reference: 218156231 | 16.50 | 9.70 | 18000 | 1.80 | EPA 4576049 → |
MAAHE-H24B-AA-UC+ furnace: MGV80M040A3ACold climate designationAHRI reference: 218155935 | 16.50 | 9.30 | 18000 | 1.80 | EPA 4576161 → |
MAAHE-H24B-BA+ furnace: RL18080B12MPS1Cold climate designationAHRI reference: 218155475 | 16.50 | 9.90 | 19000 | 1.90 | EPA 4576397 → |
MAAHE-H24B-AA+ furnace: RL18040A12MPS1Cold climate designationAHRI reference: 218155473 | 16.50 | 9.70 | 18000 | 1.80 | EPA 4576399 → |
MAAHE-H24B-AA+ furnace: MGV80M040A3ACold climate designationAHRI reference: 218155177 | 16.50 | 9.30 | 18000 | 1.80 | EPA 4576511 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →