MO1HE-H18B-2A
MAU Series · MO1 Series · source records, page 2
120 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for MO1HE-H18B-2A. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 120 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19.3 | 120 / 120 |
| EER2 · BTU/Wh | 10.8–12.5 | 120 / 120 |
| HSPF2 · BTU/Wh | 8.9–10.8 | 120 / 120 |
| Cooling capacity · BTU/h | 18,000 | 120 / 120 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 18,000–19,000 | 120 / 120 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 13,000–15,300 | 120 / 120 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,000–19,600 | 120 / 120 |
| COP at 5°F / −15°C | 1.7–2.12 | 120 / 120 |
| Equipment / loop type | HP - Split System | 120 / 120 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 120 / 120 |
| Compressor staging | Continuously variable | 120 / 120 |
| Connected capability | No | 120 / 120 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
MAAHE-H24B-BA-UC+ furnace: S9V2B040D3VS***Cold climate designationAHRI reference: 218155986 | 17.30 | 9.30 | 18000 | 1.80 | EPA 4576149 → |
MAAHE-H24B-BA+ furnace: S9V2B060D3VS***Cold climate designationAHRI reference: 218155230 | 17.30 | 9.10 | 18000 | 1.80 | EPA 4576497 → |
MAAHE-H24B-BA+ furnace: S9V2B040D3VS***Cold climate designationAHRI reference: 218155228 | 17.30 | 9.30 | 18000 | 1.80 | EPA 4576499 → |
MAAHE-H24B-BA-UC+ furnace: ML193DF070XE36B*Cold climate designationAHRI reference: 218156430 | 17.20 | 9.90 | 18000 | 1.80 | EPA 4576017 → |
MAAHE-H24B-BA+ furnace: ML193DF070XE36B*Cold climate designationAHRI reference: 218155672 | 17.20 | 9.90 | 18000 | 1.80 | EPA 4576367 → |
MAAHE-H24B-BA-UC+ furnace: ML296UH070XV36B*Cold climate designationAHRI reference: 218156449 | 17.00 | 9.90 | 19000 | 1.80 | EPA 4575998 → |
MAAHE-H24B-BA-UC+ furnace: ML193DF045XE36B*Cold climate designationAHRI reference: 218156429 | 17.00 | 9.80 | 18000 | 1.80 | EPA 4576018 → |
MAAHE-H24B-AA-UC+ furnace: RL18060A12MPS1Cold climate designationAHRI reference: 218156232 | 17.00 | 9.60 | 18000 | 1.80 | EPA 4576048 → |
MAAHE-H24B-BA+ furnace: ML296UH070XV36B*Cold climate designationAHRI reference: 218155691 | 17.00 | 9.90 | 19000 | 1.80 | EPA 4576348 → |
MAAHE-H24B-BA+ furnace: ML193DF045XE36B*Cold climate designationAHRI reference: 218155671 | 17.00 | 9.80 | 18000 | 1.80 | EPA 4576368 → |
MAAHE-H24B-AA+ furnace: RL18060A12MPS1Cold climate designationAHRI reference: 218155474 | 17.00 | 9.60 | 18000 | 1.80 | EPA 4576398 → |
MAAHE-H24B-BA-UC+ furnace: ML296UH045XV36B*Cold climate designationAHRI reference: 218156448 | 16.90 | 9.60 | 18000 | 1.80 | EPA 4575999 → |
MAAHE-H24B-BA+ furnace: ML296UH045XV36B*Cold climate designationAHRI reference: 218155690 | 16.90 | 9.60 | 18000 | 1.80 | EPA 4576349 → |
MAAHE-H24B-AA-UC+ furnace: W801V060AM3SGACold climate designationAHRI reference: 218741639 | 16.90 | 9.40 | 18000 | 1.80 | EPA 4695925 → |
MAAHE-H24B-AA+ furnace: W801V060AM3SGACold climate designationAHRI reference: 218741607 | 16.90 | 9.40 | 18000 | 1.80 | EPA 4695940 → |
MAAHE-H24B-AA-UC+ furnace: MGV80M060A3NBCold climate designationAHRI reference: 218741575 | 16.90 | 9.40 | 18000 | 1.80 | EPA 4695955 → |
MAAHE-H24B-AA+ furnace: MGV80M060A3NBCold climate designationAHRI reference: 218741543 | 16.90 | 9.40 | 18000 | 1.80 | EPA 4695970 → |
MAPHE-H18B-2ACold climate designationAHRI reference: 216623533 | 16.80 | 10.50 | 19000 | 1.80 | EPA 3892477 → |
MAAHE-H24B-BA-UC+ furnace: ML193UH070XE36B*Cold climate designationAHRI reference: 218156433 | 16.80 | 9.70 | 18000 | 1.80 | EPA 4576014 → |
MAAHE-H24B-AA-UC+ furnace: C30-2-VCold climate designationAHRI reference: 218155905 | 16.80 | 9.10 | 18000 | 1.80 | EPA 4576174 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.