MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 3

71 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.571 / 71
EER2 · BTU/Wh11.7–1371 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h54,000–58,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50071 / 71
Heating capacity at 5°F / −15°C · BTU/h29,600–31,60071 / 71
COP at 5°F / −15°C2.1–2.3471 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)71 / 71
Compressor stagingTwo-stage71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X60M24A*+ furnace: *80MSU1002120A*AHRI reference: 21562911916.008.00296002.30EPA 3951030 →
EA*5X60M24A*+ furnace: *80CTL0902120B*AHRI reference: 21562914916.008.00300002.30EPA 3951050 →
EA*5X60M24A*+ furnace: *80CTL1102120B*AHRI reference: 21562916316.008.00300002.25EPA 3951063 →
EA*5X60M24A*+ furnace: *80CTL1352422B*AHRI reference: 21562917716.008.00300002.30EPA 3951079 →
EA*5X61M21A*+ furnace: *95MSU0802120A*AHRI reference: 21562986416.008.00302002.25EPA 3951107 →
EA*5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562988316.008.00302002.30EPA 3951128 →
EA*5X61M21A*+ furnace: *96CTN1002122B*AHRI reference: 21562992716.008.00304002.25EPA 3951157 →
EA*5X60M24A*+ furnace: *97CMN1002122B*AHRI reference: 21562928916.008.00300002.25EPA 3951170 →
EA*5X60M24A*+ furnace: *95MSU0802120A*AHRI reference: 21562935916.008.00300002.25EPA 3951246 →
EA*5X60M24A*+ furnace: *95MSU1002120A*AHRI reference: 21562937816.008.00300002.25EPA 3951314 →
EA*5X60M24A*+ furnace: *95MSU1002122A*AHRI reference: 21562939416.008.00296002.30EPA 3951333 →
EA*5X60M24A*+ furnace: *96CTN1002122B*AHRI reference: 21562942216.008.00300002.25EPA 3951346 →
EA*5X60M24A*+ furnace: *96CTN1202422B*AHRI reference: 21562943616.008.00298002.25EPA 3951362 →
EA*5X60M24A*+ furnace: OLV154F20AAHRI reference: 21562951716.008.00302002.25EPA 3951512 →
EA*5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562960216.008.00304002.25EPA 3951559 →
EA*5X61M24A*+ furnace: *80CTL0702120B*AHRI reference: 21563009516.008.00306002.25EPA 3951602 →
EA*5X61M24A*+ furnace: *95CSU0802120B*AHRI reference: 21563019316.008.00304002.25EPA 3951700 →
EA*5X61M24A*+ furnace: *97CMN0802120B*AHRI reference: 21563023516.008.00302002.25EPA 3951728 →
EA*5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562964016.008.00302002.25EPA 3951738 →
EA*5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562968416.008.00304002.25EPA 3951755 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →