MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T60*K*AAA*

2-STAGE 18 SEER HP · source records, page 2

71 published source records · source checked Sep 21, 2026

SEER2 range15.5–17.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity54,000–58,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T60*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 71 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.5–17.571 / 71
EER2 · BTU/Wh11.7–1371 / 71
HSPF2 · BTU/Wh7.8–8.571 / 71
Cooling capacity · BTU/h54,000–58,00071 / 71
Heating capacity at 47°F / 8.3°C · BTU/h56,500–61,50071 / 71
Heating capacity at 17°F / −8.3°C · BTU/h36,200–38,50071 / 71
Heating capacity at 5°F / −15°C · BTU/h29,600–31,60071 / 71
COP at 5°F / −15°C2.1–2.3471 / 71
Equipment / loop typeHP - Split System71 / 71
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)71 / 71
Compressor stagingTwo-stage71 / 71
Connected capabilityNo71 / 71

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVD5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562709316.008.10304002.22EPA 3949979 →
EVD5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562716916.008.10306002.20EPA 3950110 →
EVD5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562728916.008.10302002.22EPA 3950127 →
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562583416.008.10300002.22EPA 3950201 →
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562585316.008.10298002.24EPA 3950218 →
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562587216.008.10304002.24EPA 3950240 →
EVM5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562591616.008.10304002.22EPA 3950255 →
EVM5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562593016.008.10304002.24EPA 3950270 →
EVM5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562599216.008.10300002.24EPA 3950300 →
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562611516.008.10302002.22EPA 3950317 →
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562613116.008.10302002.22EPA 3950333 →
EVM5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562655116.008.50316002.32EPA 3950376 →
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562779016.008.10306002.22EPA 3950559 →
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562780916.008.10310002.20EPA 3950643 →
EVD5X61M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562791516.008.10308002.20EPA 3950678 →
EVD5X61M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562801916.008.10314002.18EPA 3950696 →
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562803516.008.10310002.20EPA 3950712 →
EVD5X61M24A*+ furnace: *80MSU0802120A*AHRI reference: 21562818216.008.50316002.34EPA 3950756 →
EA*5X60M24A*+ furnace: *95CSU1002122B*AHRI reference: 21562924716.008.00296002.30EPA 3950936 →
EA*5X60M24A*+ furnace: *97CMN0802120B*AHRI reference: 21562927516.008.00300002.25EPA 3950948 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.