MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T48*K*AAA*

2-STAGE 18 SEER HP · source records, page 2

243 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity45,500–50,500BTU/h

Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18243 / 243
EER2 · BTU/Wh11.7–13.5243 / 243
HSPF2 · BTU/Wh7.8–8.5243 / 243
Cooling capacity · BTU/h45,500–50,500243 / 243
Heating capacity at 47°F / 8.3°C · BTU/h48,500–52,500243 / 243
Heating capacity at 17°F / −8.3°C · BTU/h30,000–32,600243 / 243
Heating capacity at 5°F / −15°C · BTU/h23,800–26,600243 / 243
COP at 5°F / −15°C2.06–2.32243 / 243
Equipment / loop typeHP - Split System243 / 243
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)243 / 243
Compressor stagingTwo-stage243 / 243
Connected capabilityNo243 / 243

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EVM5X49M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562338617.008.10250002.10EPA 3947708 →
EVM5X49M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562349017.008.10252002.10EPA 3947800 →
EVM5X49M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562355217.008.10252002.10EPA 3947863 →
EVM5X49M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562356817.008.10248002.12EPA 3947951 →
EVM5X49M21A*+ furnace: *96CTN1002122B*AHRI reference: 21562359617.008.10252002.10EPA 3947976 →
EVD5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 21562410617.008.10240002.14EPA 3948098 →
EVM5X60M21A*+ furnace: *80CSU1002120A*AHRI reference: 21562365917.008.10252002.08EPA 3948147 →
EVM5X60M21A*+ furnace: *80MSU0601716A*AHRI reference: 21562370217.008.10250002.10EPA 3948265 →
EVM5X60M21A*+ furnace: *80MSU1002120A*AHRI reference: 21562374017.008.10248002.10EPA 3948302 →
EVM5X60M21A*+ furnace: *80CTL0902120B*AHRI reference: 21562377017.008.10244002.14EPA 3948332 →
EVM5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562378417.008.10250002.10EPA 3948344 →
EVM5X60M21A*+ furnace: *95CSU1002122B*AHRI reference: 21562384617.008.10246002.12EPA 3948474 →
EVM5X60M21A*+ furnace: *97CMN1002122B*AHRI reference: 21562388817.008.10252002.10EPA 3948499 →
EVM5X60M21A*+ furnace: *95MSU1002120A*AHRI reference: 21562395017.008.10248002.12EPA 3948564 →
EVM5X60M21A*+ furnace: *95MSU1002122A*AHRI reference: 21562396617.008.10244002.16EPA 3948581 →
EVM5X60M21A*+ furnace: *96CTN0802120B*AHRI reference: 21562398017.008.10252002.10EPA 3948594 →
EVM5X60M21A*+ furnace: *96CTN1002122B*AHRI reference: 21562399417.008.10252002.10EPA 3948609 →
EVD5X60M21A*+ furnace: *80CTL1102120B*AHRI reference: 21562482117.008.10250002.10EPA 3948867 →
EVD5X60M21A*+ furnace: *97CMN0802120B*AHRI reference: 21562488117.008.10252002.08EPA 3948911 →
EVD5X49M24A*+ furnace: *95MSU1002122A*AHRI reference: 21562463717.008.10248002.12EPA 3948951 →