N5H8T48*K*AAA*
2-STAGE 18 SEER HP
243 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for N5H8T48*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 243 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 243 / 243 |
| EER2 · BTU/Wh | 11.7–13.5 | 243 / 243 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 243 / 243 |
| Cooling capacity · BTU/h | 45,500–50,500 | 243 / 243 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 48,500–52,500 | 243 / 243 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 30,000–32,600 | 243 / 243 |
| Heating capacity at 5°F / −15°C · BTU/h | 23,800–26,600 | 243 / 243 |
| COP at 5°F / −15°C | 2.06–2.32 | 243 / 243 |
| Equipment / loop type | HP - Split System | 243 / 243 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 243 / 243 |
| Compressor staging | Two-stage | 243 / 243 |
| Connected capability | No | 243 / 243 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
FTMA5B60L0D*AHRI reference: 215560726 | 18.00 | 8.10 | 24600 | 2.32 | EPA 3982815 → |
QFVA5D6021X*AHRI reference: 218695452 | 18.00 | 8.50 | 25800 | 2.32 | EPA 4683375 → |
EVM5X49M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623323 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3947647 → |
EVM5X60M21A*+ furnace: *80MSU0802120A*AHRI reference: 215623721 | 17.50 | 8.10 | 24400 | 2.14 | EPA 3948280 → |
EVD5X49M24A*+ furnace: *80MSU0802120A*AHRI reference: 215624479 | 17.50 | 8.10 | 24600 | 2.14 | EPA 3948719 → |
EVD5X61M21A*+ furnace: *80MSU0601716A*AHRI reference: 215625051 | 17.50 | 8.10 | 25000 | 2.12 | EPA 3949262 → |
EVD5X61M21A*+ furnace: *80MSU0802120A*AHRI reference: 215625070 | 17.50 | 8.50 | 24400 | 2.30 | EPA 3949283 → |
EVD5X61M21A*+ furnace: *80MSU1002120A*AHRI reference: 215625089 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949301 → |
EVD5X61M21A*+ furnace: *80CTL0902120B*AHRI reference: 215625119 | 17.50 | 8.50 | 25200 | 2.24 | EPA 3949330 → |
EVD5X61M21A*+ furnace: *80CTL1102120B*AHRI reference: 215625133 | 17.50 | 8.50 | 25000 | 2.24 | EPA 3949344 → |
EVD5X61M21A*+ furnace: *95MSU1002122A*AHRI reference: 215625301 | 17.50 | 8.10 | 24400 | 2.16 | EPA 3949600 → |
EVD5X61M24A*+ furnace: *80CTL1352422B*AHRI reference: 215625478 | 17.50 | 8.50 | 24800 | 2.28 | EPA 3949813 → |
EVD5X61M24A*+ furnace: *95MSU1002122A*AHRI reference: 215625667 | 17.50 | 8.50 | 25000 | 2.26 | EPA 3949997 → |
EVD5X61M21A*+ furnace: *80CSU0802120B*AHRI reference: 215722319 | 17.50 | 8.00 | 24800 | 2.26 | EPA 3982531 → |
EVD5X61M24A*+ furnace: *80CSU0802120B*AHRI reference: 215722422 | 17.50 | 8.00 | 24600 | 2.28 | EPA 3982632 → |
QFVA5D4821X*AHRI reference: 218695435 | 17.50 | 8.10 | 25400 | 2.18 | EPA 4683392 → |
EVM5X48M21A*+ furnace: *80MSU0802120A*AHRI reference: 215622966 | 17.00 | 8.10 | 24000 | 2.14 | EPA 3947368 → |
EVM5X49M21A*+ furnace: *80MSU0601716A*AHRI reference: 215623304 | 17.00 | 8.10 | 25000 | 2.12 | EPA 3947629 → |
EVM5X49M21A*+ furnace: *80MSU1002120A*AHRI reference: 215623342 | 17.00 | 8.10 | 24800 | 2.10 | EPA 3947665 → |
EVM5X49M21A*+ furnace: *80CTL0902120B*AHRI reference: 215623372 | 17.00 | 8.10 | 25200 | 2.10 | EPA 3947694 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →