MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 9

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5266 / 266
EER2 · BTU/Wh11.5–14266 / 266
HSPF2 · BTU/Wh7.8–8.5266 / 266
Cooling capacity · BTU/h22,200–25,000266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h24,200–25,400266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,000266 / 266
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500266 / 266
COP at 5°F / −15°C1.94–2.24266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
EA*5X30M17A*+ furnace: OMV098J12*AHRI reference: 21564614416.508.00112002.00EPA 3958903 →
EA*5X36M17A*+ furnace: *95MSU0401712A*AHRI reference: 21564666516.508.00110002.05EPA 3959423 →
EA*5X36M17A*+ furnace: OLV098A12*AHRI reference: 21564690816.508.10112002.02EPA 3959658 →
EA*5X36M17A*+ furnace: OMV098J12*AHRI reference: 21564692916.508.10113002.04EPA 3959677 →
ESH5X30M12A*+ furnace: *97CMN1002122B*AHRI reference: 21565101116.507.80110002.08EPA 3962649 →
ESH5X30M12A*+ furnace: *80CTL0901716B*AHRI reference: 21565063916.507.80110002.08EPA 3962993 →
ESH5X30M12A*+ furnace: *80MSU0401712A*AHRI reference: 21565045316.508.00110002.08EPA 3963109 →
ESH5X30M12A*+ furnace: *80MSU0601716A*AHRI reference: 21565048016.507.80111002.08EPA 3963114 →
ESH5X30M12A*+ furnace: *80MSU0802120A*AHRI reference: 21565050716.507.80110002.08EPA 3963214 →
ESH5X30M12A*+ furnace: *80CTL0701412B*AHRI reference: 21565057816.508.00110002.06EPA 3963257 →
ESH5X30M12A*+ furnace: *80CTL0701716B*AHRI reference: 21565059816.507.80110002.08EPA 3963263 →
ESH5X30M12A*+ furnace: *97CMN0801714B*AHRI reference: 21565096916.507.80111002.08EPA 3963329 →
ESH5X30M12A*+ furnace: *95MSU0601716A*AHRI reference: 21565123816.507.80110002.08EPA 3963668 →
ESH5X30M12A*+ furnace: *95MSU0802120A*AHRI reference: 21565126616.508.00112002.06EPA 3963692 →
ESH5X30M12A*+ furnace: *95MSU1002120A*AHRI reference: 21565129316.508.00111002.08EPA 3963701 →
ESH5X30M12A*+ furnace: *95MSU1002122A*AHRI reference: 21565131616.507.80110002.10EPA 3963721 →
ESH5X30M12A*+ furnace: *96CTN0801714B*AHRI reference: 21565138216.508.00111002.06EPA 3963738 →
ESH5X30M12A*+ furnace: *96CTN1002122B*AHRI reference: 21565142316.507.80110002.08EPA 3963761 →
ESH5X36M12A*+ furnace: *80CTL0902120B*AHRI reference: 21565214016.507.80110002.08EPA 3964078 →
ESH5X36M12A*+ furnace: *80CTL1352422B*AHRI reference: 21565218316.507.80110002.08EPA 3964098 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →