MARATHERM / AIR-SOURCE HEAT PUMP

N5H8T24*K*AAA*

2-STAGE 18 SEER HP · source records, page 10

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–18.5BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity22,200–25,000BTU/h

Each efficiency range summarizes published EPA records for N5H8T24*K*AAA*. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18.5266 / 266
EER2 · BTU/Wh11.5–14266 / 266
HSPF2 · BTU/Wh7.8–8.5266 / 266
Cooling capacity · BTU/h22,200–25,000266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h24,200–25,400266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h14,200–15,000266 / 266
Heating capacity at 5°F / −15°C · BTU/h10,700–11,500266 / 266
COP at 5°F / −15°C1.94–2.24266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
ESH5X36M12A*+ furnace: *95CSU1002122B*AHRI reference: 21565238916.507.80110002.08EPA 3964346 →
ESH5X36M12A*+ furnace: *97CMN0802120B*AHRI reference: 21565247116.507.80110002.08EPA 3964352 →
ESH5X36M12A*+ furnace: *97CMN1002122B*AHRI reference: 21565249216.507.80109002.08EPA 3964369 →
ESH5X30M12A*+ furnace: OMV098J12*AHRI reference: 21565172316.508.00115002.05EPA 3964466 →
ESH5X36M12A*+ furnace: *80MSU0401712A*AHRI reference: 21565192816.507.80110002.08EPA 3964718 →
ESH5X36M12A*+ furnace: *80MSU0601716A*AHRI reference: 21565195616.507.80109002.10EPA 3964739 →
ESH5X36M12A*+ furnace: *96CTN1002122B*AHRI reference: 21565290016.507.80109002.08EPA 3965098 →
ESH5X36M12A*+ furnace: *96CTN1202422B*AHRI reference: 21565292016.507.80110002.08EPA 3965117 →
ESH5X36M12A*+ furnace: *95MSU0802120A*AHRI reference: 21565274716.507.80110002.08EPA 3965623 →
EA*5X24M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572034316.508.00110002.06EPA 3980082 →
EA*5X24M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572035716.508.10111002.05EPA 3980093 →
EA*5X24M17A*+ furnace: *97CTN0801716A*AHRI reference: 21572037116.508.00111002.04EPA 3980112 →
EA*5X30M17A*+ furnace: *80CSU0601716B*AHRI reference: 21572052716.507.80109002.06EPA 3980898 →
EA*5X30M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572054116.508.10111002.05EPA 3980912 →
EA*5X36M17A*+ furnace: *97CTN0601716A*AHRI reference: 21572063316.508.00110002.06EPA 3981006 →
EA*5X25M17A*+ furnace: *97CTN0401410A*AHRI reference: 21799188716.508.00113002.06EPA 4566262 →
F5MA5*24L*B*AHRI reference: 21646426816.008.10110002.08EPA 3847180 →
EA*5X24M17A*+ furnace: OLV098A12*AHRI reference: 21564431416.008.10113002.00EPA 3957727 →
EA*5X24M17A*+ furnace: OMV098J12*AHRI reference: 21564433616.008.10113002.02EPA 3957743 →
EA*5X36M17A*+ furnace: *96CTN0401410B*AHRI reference: 21564671616.008.00113002.00EPA 3959460 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →