Luxaire / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 23

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16461 / 461
EER2 · BTU/Wh11.7–12461 / 461
HSPF2 · BTU/Wh7.8–8.1461 / 461
Cooling capacity · BTU/h39,500–42,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600461 / 461
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600461 / 461
COP at 5°F / −15°C1.98–2.42461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-410A (GWP:2088)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60GBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21247782515.208.10210002.28EPA 3990739 →
XAFD60GBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247783515.208.10210002.28EPA 3990741 →
XAHD60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21247786115.208.10220002.34EPA 3990748 →
XAHD60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21247786615.208.10220002.34EPA 3990751 →
XAFC60GBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248822515.208.10212002.24EPA 3990884 →
XAHC60GBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21248825115.208.10220002.34EPA 3990888 →
XAHC60GBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248825615.208.10220002.34EPA 3990895 →
XAFC60GBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248834715.208.10208002.24EPA 3990922 →
XAFC60GBCN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248835715.208.10208002.24EPA 3990923 →
XAFC60GBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259419815.208.10208002.24EPA 3991073 →
XAHC60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21248242115.208.10220002.36EPA 3991123 →
XAHC60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248243315.208.10220002.36EPA 3991128 →
XAHD60GBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21247788515.208.10220002.34EPA 3991153 →
XAHD60GBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21247789015.208.10220002.34EPA 3991162 →
XAFD60GXXN1+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21259431815.208.10208002.28EPA 3991236 →
XAFD60GBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21259432315.208.10208002.28EPA 3991238 →
XAHC60GBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259433815.208.10218002.32EPA 3991244 →
XAHD60GBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21259449315.208.10218002.34EPA 3991572 →
XAHC60GBCN1+ furnace: Z9ET100C16SMPS1AHRI reference: 21637519115.207.80214002.30EPA 3992192 →
XAHD60GBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21637519415.207.80218002.34EPA 3992193 →