Luxaire / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 22

461 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 461 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16461 / 461
EER2 · BTU/Wh11.7–12461 / 461
HSPF2 · BTU/Wh7.8–8.1461 / 461
Cooling capacity · BTU/h39,500–42,000461 / 461
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000461 / 461
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600461 / 461
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600461 / 461
COP at 5°F / −15°C1.98–2.42461 / 461
Equipment / loop typeHP - Split System461 / 461
Refrigerant / source-reported GWPR-410A (GWP:2088)461 / 461
Compressor stagingTwo-stage461 / 461
Connected capabilityNo461 / 461

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60GBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21247505115.208.10212002.26EPA 3990578 →
XAFD60GXXN1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21247500715.208.10212002.26EPA 3990591 →
XAFD60GXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21247501715.208.10212002.26EPA 3990594 →
XAFD60GBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21247503115.208.10212002.26EPA 3990602 →
XAFD60GXXN1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21248528115.208.10212002.26EPA 3990604 →
XAFD60GXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21248528615.208.10212002.26EPA 3990611 →
XAFD60GBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21248529315.208.10212002.26EPA 3990616 →
XAFD60GBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248530315.208.10212002.26EPA 3990621 →
XAHD60GBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 21248532915.208.10220002.34EPA 3990624 →
XAHD60GBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248533415.208.10220002.34EPA 3990630 →
XAFD60GXXN1+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21248534115.208.10210002.28EPA 3990635 →
XAFD60GXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21248534615.208.10210002.28EPA 3990640 →
XAFD60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21248535315.208.10210002.28EPA 3990643 →
XAHD60GBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21247515015.208.10218002.36EPA 3990650 →
XAHD60GBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247516015.208.10218002.36EPA 3990652 →
XAFD60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248536315.208.10210002.28EPA 3990660 →
XAHC60GBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248542515.208.10218002.32EPA 3990685 →
XAFC60GBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21248821515.208.10212002.24EPA 3990708 →
XAFD60GXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21247781315.208.10210002.28EPA 3990726 →
XAFD60GXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21247781815.208.10210002.28EPA 3990729 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →