Luxaire / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 15

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+TXV+ furnace: TPLC100C16MP13AHRI reference: 21868955417.008.10340002.20EPA 4677827 →
CTF60C5CGS2+ furnace: TM9V100C16MP12AHRI reference: 21868953817.008.10338002.20EPA 4677837 →
CTU60C5XGS2+TXV+ furnace: TM9V100C16MP12AHRI reference: 21868953717.008.10338002.20EPA 4677838 →
CTF60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 21868953317.008.10395002.26EPA 4677839 →
CTM60D5CJS2+ furnace: TM9V120D20MP12AHRI reference: 21868953217.008.10400002.28EPA 4677840 →
CTM60C5CGS2+ furnace: TM9V080C16MP12AHRI reference: 21868952617.008.10342002.18EPA 4677844 →
CTF60C5CGS2+ furnace: TMLV100C16MP12AHRI reference: 21868952217.008.10340002.20EPA 4677848 →
CTU60C5XGS2+TXV+ furnace: TMLV100C16MP12AHRI reference: 21868952117.008.10340002.20EPA 4677849 →
CTF60C5CGS2+ furnace: TM8V100C16MP12AHRI reference: 21868951217.008.10340002.20EPA 4677856 →
CTU60C5XGS2+TXV+ furnace: TM8V100C16MP12AHRI reference: 21868951117.008.10340002.20EPA 4677857 →
CTU60C5XGS2+TXV+ furnace: TM8V080C16MP12AHRI reference: 21868950717.008.10340002.20EPA 4677859 →
CTF60C5CGS2+ furnace: TM8V080C16MP12AHRI reference: 21868950617.008.10340002.20EPA 4677860 →
CTF60C5CGS2+ furnace: TL8E080C16UH11AHRI reference: 21868950417.008.10342002.20EPA 4677862 →
CTU60C5XGS2+TXV+ furnace: TL8E080C16UH11AHRI reference: 21868950317.008.10342002.20EPA 4677863 →
CTM60C5CGS2+ furnace: TL8E080C16UH11AHRI reference: 21868950217.008.10342002.20EPA 4677864 →
CTM60C5CGS2+ furnace: TL9E080C16UH11AHRI reference: 21868950117.008.10346002.20EPA 4677865 →
CTU60C5XGS2+TXV+ furnace: TL8E100C20UH11AHRI reference: 21868949717.008.10350002.26EPA 4677867 →
CTF60C5CGS2+ furnace: TL8E100C20UH11AHRI reference: 21868949617.008.10350002.26EPA 4677868 →
CTF60C5CGS2+ furnace: TL9E080C16UH11AHRI reference: 21868949517.008.10344002.20EPA 4677869 →
CTU60C5XGS2+TXV+ furnace: TL9E080C16UH11AHRI reference: 21868949417.008.10344002.20EPA 4677870 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →