Luxaire / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 14

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21864201517.008.10342002.20EPA 4665690 →
CTF60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21864197917.008.10344002.24EPA 4665726 →
CTM60C5CGS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21864195917.008.10346002.22EPA 4665746 →
CTF60C5CGS2+ furnace: LP9C100C16MP13AHRI reference: 21868961217.008.10338002.20EPA 4677789 →
CTU60C5XGS2+TXV+ furnace: LP9C100C16MP13AHRI reference: 21868961117.008.10338002.20EPA 4677790 →
CTF60C5CGS2+ furnace: LPLC080C16MP13AHRI reference: 21868960917.008.10340002.20EPA 4677792 →
CTF60C5CGS2+ furnace: LPLC100C16MP13AHRI reference: 21868960717.008.10340002.20EPA 4677794 →
CTU60C5XGS2+TXV+ furnace: LPLC080C16MP13AHRI reference: 21868960317.008.10340002.20EPA 4677796 →
CTU60C5XGS2+TXV+ furnace: LPLC100C16MP13AHRI reference: 21868960217.008.10340002.20EPA 4677797 →
CTM60D5CJS2+ furnace: LP9C120D20MP13AHRI reference: 21868959817.008.10400002.28EPA 4677798 →
CTF60D5CJS2+ furnace: LP9C120D20MP13AHRI reference: 21868959717.008.10395002.26EPA 4677799 →
CTM60C5CGS2+ furnace: LP9C080C16MP13AHRI reference: 21868959117.008.10342002.18EPA 4677803 →
CTF60C5CGS2+ furnace: TP9C100C16MP13AHRI reference: 21868958217.008.10338002.20EPA 4677808 →
CTU60C5XGS2+TXV+ furnace: TP9C100C16MP13AHRI reference: 21868958117.008.10338002.20EPA 4677809 →
CTU60C5XGS2+TXV+ furnace: TPLC080C16MP13AHRI reference: 21868957317.008.10340002.20EPA 4677815 →
CTF60C5CGS2+ furnace: TPLC080C16MP13AHRI reference: 21868957217.008.10340002.20EPA 4677816 →
CTM60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 21868956717.008.10400002.28EPA 4677818 →
CTF60D5CJS2+ furnace: TP9C120D20MP13AHRI reference: 21868956517.008.10395002.26EPA 4677820 →
CTM60C5CGS2+ furnace: TP9C080C16MP13AHRI reference: 21868956017.008.10342002.18EPA 4677823 →
CTF60C5CGS2+ furnace: TPLC100C16MP13AHRI reference: 21868955517.008.10340002.20EPA 4677826 →