Luxaire / AIR-SOURCE HEAT PUMP

HH836E2S11

LX SERIES · source records, page 45

927 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8–9.5BTU/Wh
Cooling capacity31,600–35,000BTU/h

Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19927 / 927
EER2 · BTU/Wh10–12927 / 927
HSPF2 · BTU/Wh8–9.5927 / 927
Cooling capacity · BTU/h31,600–35,000927 / 927
Heating capacity at 47°F / 8.3°C · BTU/h30,000–33,400927 / 927
Heating capacity at 17°F / −8.3°C · BTU/h25,400–29,600927 / 927
Heating capacity at 5°F / −15°C · BTU/h22,200–27,200927 / 927
COP at 5°F / −15°C2–2.1927 / 927
Equipment / loop typeHP - Split System927 / 927
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)927 / 927
Compressor stagingContinuously variable927 / 927
Connected capabilityNo927 / 927

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5CDS2+ furnace: TM9V060B12MP12AHRI reference: 21852117517.008.50252002.00EPA 4644401 →
CTF36B5ADS2+ furnace: LP9C060B12MP13AHRI reference: 21852117317.008.50252002.00EPA 4644403 →
CTF36B5ADS2+ furnace: TP9C060B12MP13AHRI reference: 21852116917.008.50252002.00EPA 4644407 →
CTF36B5ADS2+ furnace: TM9V060B12MP12AHRI reference: 21852116517.008.50252002.00EPA 4644411 →
CTU36B5XDS2+TXV+ furnace: TM8V080B12MP12AHRI reference: 21852113117.008.50252002.00EPA 4644445 →
CTF36B5CDS2+ furnace: TM8V080B12MP12AHRI reference: 21852112717.008.50252002.00EPA 4644449 →
CTF36B5ADS2+ furnace: LPLC080B12MP13AHRI reference: 21852112517.008.50252002.00EPA 4644451 →
CTF36B5ADS2+ furnace: TPLC080B12MP13AHRI reference: 21852112117.008.50252002.00EPA 4644455 →
CTF36B5ADS2+ furnace: TM8V080B12MP12AHRI reference: 21852111717.008.50252002.00EPA 4644459 →
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1AHRI reference: 21852106517.008.50254002.00EPA 4644511 →
CTF36B5CDS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852106117.008.50254002.00EPA 4644515 →
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852105717.008.50254002.00EPA 4644519 →
CTF30A5ADS2+ furnace: TM8V060A12MP12AHRI reference: 21852104117.008.50252002.00EPA 4644535 →
CTM36B5CDS2+ furnace: TM8V080B12MP12AHRI reference: 21852264317.008.50252002.00EPA 4644814 →
CTM36B5ADS2+ furnace: LPLC080B12MP13AHRI reference: 21852264117.008.50252002.00EPA 4644816 →
CTM36B5ADS2+ furnace: TPLC080B12MP13AHRI reference: 21852263717.008.50252002.00EPA 4644820 →
CTM36B5ADS2+ furnace: TM8V080B12MP12AHRI reference: 21852263317.008.50252002.00EPA 4644824 →
CTM36B5CDS2+ furnace: LP9C080B12MP13AHRI reference: 21852263117.008.50250002.00EPA 4644826 →
CTM36B5CDS2+ furnace: TP9C080B12MP13AHRI reference: 21852262717.008.50250002.00EPA 4644830 →
CTM36B5CDS2+ furnace: TM9V080B12MP12AHRI reference: 21852262317.008.50250002.00EPA 4644834 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →